HP Pro Tower 400 G9 PCI Desktop PC Maintenance and Service Guide - Page 119

Specifications, Table 13-1

Page 119 highlights

13 Specifications This section provides specifications for your computer. Table 13-1 Specifications Metric U.S. Dimensions Height Width Depth Approximate weight 337 mm 155 mm 308 mm 13.27 in 6.1 in 12.13 in 1 DDR, HDD, ODD 2 DDR, 2 HDD, ODD, graphic card Temperature range 5.31 kg 6.58 kg 11.71 lb 14.5 lb Operating Nonoperating 10°C to 35°C -30°C to 60°C 50°F to 95°F -22°F to 140°F NOTE: Operating temperature is derated 1.0°C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/hr. The upper limit might be limited by the type and number of options installed. Maximum altitude (unpressurized) Operating 5,000 m 16,404 ft Nonoperating Relative humidity (noncondensing) 15.240 m 50,000 ft Operating Nonoperating (38.7°C max wet bulb) Power supply 10% to 90% 5% to 95% Operating voltage range Rated voltage range1 Rated line frequency Operating line frequency 90 V ac to 264 V ac 100 V ac to 240 V ac 50 Hz to 60 Hz 47 Hz to 63 Hz Standard efficiency 400 W, 92% efficient 260 W, 92% efficient 180 W, 90% efficient 1 This system uses an active power factor-corrected power supply. This allows the system to pass the CE mark requirements for use in the countries of the European Union. The active power factor-corrected power supply also has the added benefit of not requiring an input-voltage range select switch. 112 Chapter 13 Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

Specifications
13
This section provides specifications for your computer.
Table 13-1
Specifications
Metric
U.S.
Dimensions
Height
337 mm
13.27 in
Width
155 mm
6.1 in
Depth
308 mm
12.13 in
Approximate weight
1 DDR, HDD, ODD
5.31 kg
11.71 lb
2 DDR, 2 HDD, ODD, graphic card
6.58 kg
14.5 lb
Temperature range
Operating
10°C to 35°C
50°F to 95°F
Nonoperating
–30°C to 60°C
–22°F to 140°F
NOTE:
Operating temperature is derated 1.0°C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/hr. The upper limit might be limited by the type and number of options installed.
Maximum altitude (unpressurized)
Operating
5,000 m
16,404 ft
Nonoperating
15.240 m
50,000 ft
Relative humidity (noncondensing)
Operating
10% to 90%
Nonoperating (38.7°C max wet bulb)
5% to 95%
Power supply
Operating voltage range
90 V ac to 264 V ac
Rated voltage range
1
100 V ac to 240 V ac
Rated line frequency
50 Hz to 60 Hz
Operating line frequency
47 Hz to 63 Hz
Standard efficiency
400 W, 92% efficient
260 W, 92% efficient
180 W, 90% efficient
1
This system uses an active power factor-corrected power supply. This allows the system to pass the CE mark requirements for use in
the countries of the European Union. The active power factor-corrected power supply also has the added benefit of not requiring an
input-voltage range select switch.
112
Chapter 13
Specifications