HP ProLiant DL288 Configuring Arrays on HP Smart Array Controllers Reference G - Page 63
Sample scenario, Parameter, Acceptable values, Comments, Example commands
View all HP ProLiant DL288 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Parameter drives raid paritygroups ss size sectors aa drivetype Acceptable values all|allunassigned 60|50|6|adg|5|1+0|1|0|? 2|# 8|16|32|64|128|256|default|? #|max|? 32|63|default|? enable|disable|? sas|satalogical|sata|saslogical|para llelscsi|? Comments The default setting is all. The default setting is the highest RAID level that the controller model and number of drives can support, except 50 or 60 (which must be specified deliberately). The default value is 2. Units are KB.* The default setting depends on the RAID level. This parameter determines the desired size of the logical drive. Units are MB.* The default setting is max. The default setting depends on the operating system. The default setting is enable. - *Use only these units. Do not enter any extra text in the command to specify the units. If you specify an array as the target, you can omit the drives parameter, because the drives are already implicitly defined by the array ID. This feature is useful if you are entering the command directly into the CLI console because you do not need to remember which drives belong to the array. When you write a batch file, however, it is often easier to specify every drive in the array than to parse out the array ID. When you use the drives parameter you can list each drive individually, you can specify a drive range, or you can specify both a range and some individual drives. A drive range can span ports, boxes, and bays. If you specify individual drives, they do not have to form a continuous sequence. If you specify a range, the CLI automatically excludes from the target any drive in the range that is unavailable (for example, a drive is excluded if it already belongs to an array, is a spare, has too small a capacity, or has failed). If you want to specify an existing array by its drives rather than by array ID, then all of the drives that you specify must belong to the same array, and none of the drives in the array can be omitted. Example commands: ctrl slot=5 create type=ld drives=1:0,1:1,1:3 raid=adg ctrl slot=5 create type=ld drives=1:1-1:3 raid=adg ctrl slot=5 create type=ld drives=1:7,1:10-2:5,2:8-2:12 raid=adg ctrl slot=5 array A create type=ld size=330 raid=adg The following pair of commands demonstrates how the drives parameter can be used in a batch file to create two logical drives on the same array, one of 330 MB and the other of 450 MB: ctrl slot=2 create type=ld drives=1:1-1:6 size=330 raid=adg ctrl slot=2 create type=ld drives=1:1-1:6 size=450 raid=5 Sample scenario Consider a situation in which you want to create two arrays. One of these arrays needs two logical drives, while the other needs only one. HP Array Configuration Utility 63