HP ProLiant SL390s HP ProLiant SL390s G7 1U half width Server Maintenance and
HP ProLiant SL390s - G7 Server Manual
View all HP ProLiant SL390s manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant SL390s manual content summary:
- HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 1
HP ProLiant SL390s G7 1U half width Server Maintenance and Service Guide Part number 614098-001 September 2010 (First edition) - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 3
-installation instructions ...28 Server Warnings and Cautions ...28 Symbols on Equipment...29 Powering Down the Server ...30 System tray Removal 65 Rear panel LED indicators ...67 Diagnostic tools ...69 Troubleshooting resources ...69 HP Insight Diagnostics ...69 Integrated Management Log...70 Array - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 4
HP Systems Insight Manager ...70 HP Insight Remote Support software ...70 USB support and functionality ...71 USB support ...71 Internal USB functionality ...71 Internal SD support...72 Physical and Operating Specifications ...73 System Unit ...73 Index ...76 Contents 4 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 6
pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 7
due categorie di parti CSR: • Obbligatorie - Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio. • Opzionali - Parti la cui riparazione da parte del cliente è facoltativa - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 8
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 9
componentes CSR se clasifican en dos categorías: • Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 10
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSRonderdeel, verzendt - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 11
diretamente ao cliente. Existem duas categorias de peças CSR: • Obrigatória - Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. • Opcional - Peças cujo reparo feito pelo cliente é opcional - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 12
Customer self repair 12 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 13
Customer self repair 13 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 14
Customer self repair 14 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 15
Customer self repair 15 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 16
4 Right front I/O bezel None 5 SL390s 1U Right tray None 6 Top cover of power supply None 1Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 17
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 18
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 19
Illustrated parts catalog 19 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 20
System components Item Description 1 SL390s System Board 2 X24 PCIe riser card 3 X16 PCIe riser card 4 Hard Drive Options Hard Drive, SATA 160GB 7.2K LFF Hard Drive, SATA 500GB 7.2K LFF - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 21
PC3-10600R 4GB 501534-001 Mandatory1 DIMM PC3-8500R 4GB 501535-001 Mandatory1 DIMM PC3-8500R 8GB 519201-001 Mandatory1 6 Processors ,Optional Series Processor Intel X5680 3.33GHz/1333/12M/6c/6.4 QPI/130W 614739-001 Optional2 Processor Intel X5670 2.93GHz/1333/12M/6c/6.4 QPI/95W 594882 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 22
L5640 2.26GHz/1333/12M/6c/5.86 QPI/60W Processor Intel L5630 2.13GHz/1066/12M/4c/5.86 QPI/40W 7 Processor Heat Sink 8 Personality board 9 SL390s System Board Loopback Board 10 System Fan 11 Power/data Backplane board 12 1200-W Power Supply 1200-W Power Supply High Efficiency 750-W Power - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 23
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 24
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 25
Illustrated parts catalog 25 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 26
-1518. • In Canada, call 1-800-263-5868. • In other locations, refer to the HP website at http://www.hp.com/. For HP technical support: • In North America: ○ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 27
instructions correspond to the numbered labels on the related figure (i.e., label 1 corresponds to step a, label 2 corresponds to step b, etc.). The procedures described in this section assume that the server HP ProLiant SL390s G7 1U half width Server User Guide • IPMI Event Log • Diagnostics - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 28
the power button on the front panel to turn on the server. NOTE: The HP ProLiant SL390s G7 1U half width server supports up to four 750-W or 1200-W power supply units. Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 29
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. CAUTION: The following rack-mount instructions shall of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. To reduce the risk of injury from - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 30
health and safety requirements and guidelines for manual material handling. These symbols, on server. System tray Removal and Replacement Procedures The system tray is removable for a server component removal and replacement. To remove the system tray: 1. Release the handle. 2. Extend the server - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 31
Figure 1 Removing the left server Figure 2 Removing the right server To replace the system tray: 1. Insert the system tray into the chassis. Removal and Replacement Procedures 31 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 32
Figure 3 Installing the left server Figure 4 Installing the right server Drives The server supports 2 drive bays for 3.5-inch hard disk drives or 4 drive bays for 2.5-inch hard disk drives. Cable Management Always follow good cable management practices when working - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 33
The following table provides information about cable connector. Table 1 Cable connection Cable MB power cable(Left and right tray) RPS cable(Left and right tray) Front SATA cable(Left and right tray) From J2 on Personality Board J3 on Personality Board J32, J9 on MB and P1, P2 on personality - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 34
2) LFF HDD (configure 3) SFF HDD (configure 4) Hard Drives One SL390s G7 1U server tray can accommodate up to 2 LFF or 4 SFF hard disk drives, one chassis can accommodate 8 1U server trays for up to 16 LFF or 32 SFF hard disk drives. The server supports both SAS and SATA hard disk drives and SSDs - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 35
HP ProLiant SL390s G7 1U half width Server supports disk drive hot-swapping. To avoid hand contact with an electrical hazard, do not remove more than one drive carrier a time. 1. Slide the HDD carrier latches to unlock the HDD handle. 2. Raise the HDD handle. 3. Lift the HDD assembly out of the tray - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 36
to maintain proper system airflow. Front I/O bezel To remove the Front I/O bezel: 1. Unfasten the screws that secure the Front I/O bezel to the tray. 2. Remove the Front I/O bezel horizontally. Figure 9 Removing the Front I/O bezel To install the Front I/O bezel: 1. Align the Front I/O bezel to the - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 37
Figure 10 Installing the Front I/O board System Board Configuration Processor HP ProLiant SL390s G7 1U half width Server, with 8 Nodes, supports sixteen -processor operation. With two processors installed, each Node supports boot functions through the processor installed in processor socket 1. - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 38
Figure 11 Processor locations Item Description 1 Processor 1 2 Processor 2 WARNING: To reduce the risk of personal injury from hot surfaces, allow the heat sink and the processor to cool before touching them. To remove the heat sink: CAUTION: To prevent the heat sink from tilting to one side - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 39
Figure 12 Removing the heat sink assembly IMPORTANT: If the heat sink has been removed for any reason on a previously installed processor, it is critical that you clean off any residue of the old thermal compound from both the heatsink and processor with alcohol and a clean cloth and apply more - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 40
processor into the socket. The processor and system board spare part kits contain the processor install tool and instructions on how to use the tool. It is important to follow the instructions to prevent damage to the pins in the processor socket. To install the new processor: 1. Open the processor - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 41
Figure 15 Installing the processor in the installation tool 3. Align the processor installation tool with the socket and install the processor. Figure 16 Installing the processor 4. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 42
Wipe the contact surfaces several times to make sure that no particles or dust contaminants are evident. CAUTION: HP recommends using Shin-Etsu X-23-7783D thermal grease compound for your ProLiant server. 2. Apply all the grease to the top of the processor in one of the following patterns to insure - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 43
the heat sink: CAUTION: To prevent overheating or a possible system crash, use only a heat sink model specified for the HP ProLiant SL390s G7 1U half width server. 1. Properly align the heat sink mounting pins to the system board mounting holes. 2. Tighten the mounting pins clockwise to secure - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 44
Figure 20 Installing the heat sink Memory HP ProLiant SL390s G7 1U half width server has 12 DIMM slots that support up to 96 GB maximum system memory. You must adhere to the following guidelines when adding or replacing memory modules: • Support 12 DDR3 240-pin RDIMM (SR, DR, QR) or UDIMM (SR, DR) - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 45
Figure 21 DIMM slots Figure 22 DIMM Order To remove memory module: 1. Completely open the holding clips securing the module. 2. Gently pull the memory module upward to remove it from the slot. Removal and Replacement Procedures 45 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 46
Figure 23 Removing a memory module CAUTION: Place the memory module on a static-dissipating work surface or inside of an anti-static bag. To install a memory module: 1. Align the notch on the bottom edge of the module with the keyed surface of the DIMM slot and then press the module fully into the - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 47
NOTE: The ProLiant G7 1U half width server supports up to 12 memory modules. Install them in the DIMM slots starting from the DIMM 1 slot. PCI Expansion Cards System Board PCI Expansion Slots There - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 48
card 3. Install the front PCIe assembly to the server and fasten the screws. Figure 28 Installing the front PCIe assembly NOTE: Reverse the above steps for removal procedures. Battery-backed write cache procedures 1. Align the BBWC bracket to the tray and fasten the screws. Removal and Replacement - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 49
Figure 29 Installing the BBWC bracket 2. Install the BBWC into the tray and slide it in the direction of the arrow. Figure 30 Installing the BBWC 3. Connecting the BBWC cable with the smart array controllers. Removal and Replacement Procedures 49 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 50
Cable routing System Battery The server uses nonvolatile memory that battery: • Replace the battery with the same type as the battery recommended by HP. Use of another battery may present a risk of fire or explosion. • A according to manufacturer's instructions. Removal and Replacement Procedures 50 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 51
when the battery is removed. You must reconfigure BIOS settings whenever you replace the battery. NOTE: If the server no longer automatically displays the correct date and time that secure the system board to the tray. 2. Release the system board from the tray. Removal and Replacement Procedures 51 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 52
system board is removed in the future, you must keep them for future use. To replace the system board: 1. Put the system board in the tray. The screw holes on the tray should align with the holes on the system board. 2. Fasten the screws to secure the system board to the - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 53
holes on the personality board. 2. Fasten the screws to secure the personality board to the tray. Figure 37 Installing the personality board Power Supply Unit (PSU) Located on the rear panel of the server power supply is a standard ranging 750 watt or 1200 watt PSU with PFC (power factor correction - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 54
shock hazards and/or damage to the equipment. • Installation of power supply units should be referred to individuals who are qualified to service server systems and are trained to deal with equipment capable of generating hazardous energy levels. • DO NOT open the power supply unit. There are no - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 55
2. Slide the power supply out of the power supply bay. Figure 40 Removing the Power supply To replace the PSU Backplane: 1. Remove the top cover from the power supply cage. 2. Install the PSU Backplane. 3. Reinstall the top cover to the power supply cage. Figure 41 Installing the PSU Backplane To - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 56
Figure 42 Installing the power supply System Fan The server has eight system fans located on the rear panel of chassis. The figure below identifies the system fans by their device number. Figure 43 System - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 57
Item Description 5 Fan 5 6 Fan 6 7 Fan 7 8 Fan 8 A new system fan can be installed to allow the server to operate properly in case a default system fan becomes defective. To remove the system fan: 1. Squeeze the two release tabs on the system fan together - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 58
Figure 45 Installing the system fan Removal and Replacement Procedures 58 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 59
, and LED indicators located on the front panel, rear panel of the HP ProLiant SL390s G7 1U half width Server. Connectors and Components Front Panel Components Figure 46 Front panel components of SL390 1U server system Item 1 2 3 4 5 6 7 8 9 10 Description VGA port Serial port SFP PLUS connector - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 60
Item Description 11 iLO3 network port 12 UID LED/SW Rear panel components Figure 47 Rear panel components of SL390s G7 1U server system Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Power Supply 1 Power Supply 2 Power Supply 3 Power Supply 4 UID LED/SW APM connector Fan 1 Fan 2 Fan 3 Fan - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 61
System board components Figure 48 System board components Item 1 2 3 4 5 6 7 8 9 10 11 Designator Description J38 Serial port SW3 Power LED/SW J30 QSFP cage J41 Top: NIC port1 Bottom: NIC port2 J37 Top: ILO port Bottom: USB 2.0 Port SW4 UID LED/SW J12 Micro SD card U2 IB U84 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 62
Item 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Designator Description @U10, @U22, @U41, @U51, @U12, @U10, @U14, @U11 CPU2 VRD and CPU1 DIMM VRD XU2 Processor 2 socket J1 CPU1 DDR3 DIMM slot J2 CPU1 DDR3 DIMM slot J4 CPU1 DDR3 DIMM slot J5 CPU1 DDR3 DIMM slot J7 CPU1 DDR3 DIMM slot J8 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 63
. For connecting to Cylades connection, use ADB0039. For connecting to DB9M connection, use rolled cat5e and digi76000702 or manually wire with Digikey P/N 046-0000-ND. Table 2 Pin out information Item SL390s Serial port DIGI CM RJ-45 Sun RJ-45 Cisco RJ-45 Cyclades RJ-45 1 RTS CTS CTS RTS - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 64
This section contains illustration and descriptions of internal and external status LED indicators located on the: • Front panel • Rear panel These LED indicators aid in problem diagnosis by indicating the status of system components and operations of the server. Connectors, Switches, and LEDs 64 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 65
Front panel LED indicators The front panel LED indicators allow constant monitoring of basic system functions while the server is operating. Figure 49 Health LED Indicator location Table 5 Health LED indicator status Components Health LED indicator Status Red(Blinking) Amber (Blinking) Green Off - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 66
Components UID LED indicator Status Blue Blue(Blinking) Off Descriptions Identification System is being remotely managed Off Power LED Indicator The power status of the server is indicated by the bicolor LED on the front panel. Connectors, Switches, and LEDs 66 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 67
indicator location Table 7 Power/system health LED indicator status Component Power/system health LED indicator Status Steady green Description The server is operating normally. Steady Amber Steady red Off The server is system off or in hibernation with A/C power. Critical event happens to the - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 68
Figure 52 UID/LED indicator location Table 8 UID/LED indicator states Item Component UID LED indicator Status Blue Blue(Blinking) Off Description Identification System is being remotely managed Off Connectors, Switches, and LEDs 68 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 69
ProLiant SL390s G7 1U half width Server User Guide or the HP website (http://www.hp.com/support/smartstart/documentation). HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provide diagnostics and troubleshooting - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 70
Remote Support software delivers secure remote support for your HP Servers and Storage, 24 X 7, so you can spend less time solving problems and more time focused on your business. You can have your systems remotely monitored for hardware failure using secure technology that has been Diagnostic tools - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 71
/advisories and service dispatch. It is optimized for environments with 1 to 50 servers and can be installed on a shared HP ProLiant Windows application server. The software supports HP EVA storage devices, HP ProLiant, BladeSystems, HP Integrity and HP 9000 servers running Microsoft Windows - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 72
Internal SD support An internal SD connector is available for use with embedded Hypervisors. This solution provides for use of a permanently installed SD card in the internal connector, decreasing the possibility of tampering or loss. Diagnostic tools 72 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 73
This chapter provides physical and operating specifications for the HP ProLiant SL390s G7 1U half width server. Specifications include: System Unit Table 9 Hardware Specifications Item Processor socket Processor support Chipset Hardware monitoring device Gigabit Ethernet controller Memory - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 74
System board dimension Dimensions (H x W x D) (with bezel) Server weight (approximate) Description ATX (Advanced Technology Extended) 17.935''x6.5'' piece of memory, one hard drive, and one processor 8 trays installed) 55.2kg Table 11 Environmental Specifications Item Description Thermal - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 75
: To review typical system power ratings use the Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power% 20Calculator%20Catalog.xls - Click on the system of interest. Example: xxxxxx - Follow the instructions of the next screens. 75 - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 76
), 5 D diagnostic tools, 69 diagnostics utility, 69 dimensions server, 74 Drives HP authorized reseller, 26 contact information, 26 technical support, 26 technical support requirements, 26 HP Insight Diagnostics, 69 HP Insight Remote Support software, 70 HP ProLiant Essentials Foundation Pack, 70 HP - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 77
), 70 improper airflow caution, 28 Insight Diagnostics, 69 Integrated Management Log (IML), 70 Internal SD support, 72 internal USB functionality, 71 J 60 resources, 69 resources, troubleshooting, 69 S server dimensions rack, 74 server warnings and cautions, 28 SL390s System Board spare part number - HP ProLiant SL390s | HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 78
front panel, 59 rear panel, 60 system board components, 61 system tray removing, 30 replacing, 31 System Unit specifications, 73 Systems Insight Manager, 70 T thermal solution, 74 tools, 69 troubleshooting, 69 U USB support, 71 utilities, 69 W warnings battery replacement, 50 PSU replacement, 54
HP ProLiant SL390s G7 1U half width Server
Maintenance and Service Guide
Part number 614098-001
September 2010 (First edition)