HP ProLiant SL390s HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 74

Table 9, Components, Description, Dimensions H x W x D

Page 74 highlights

Table 9 Hardware Specifications Item Thermal solution Components Eight 80mm system fans Table 10 Physical Dimensions Item System board platform System board dimension Dimensions (H x W x D) (with bezel) Server weight (approximate) Description ATX (Advanced Technology Extended) 17.935''x6.5'' 6.96 x 17.64 x 35.32 inch Full loading (all memory, hard drives, power supplies, and processors installed) 68.1kg Light loading (one piece of memory, one hard drive, and one processor 8 trays installed) 55.2kg Table 11 Environmental Specifications Item Description Thermal output (maximum operating) 392 W/hr System inlet temperature Operating 50° to 95° F (10° to 35° C) at sea level with an altitude derating of 1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000 ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 86°F (30°C). System inlet temperature Non-operating 40° to 140° F (-40° to 60° C) Maximum rate of change is 36°F/hr (20°C/hr). Relative humidity (non-condensing) Operating 10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing. Relative humidity (non-condensing) Non-operating 10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet bulb temperature, non-condensing. Altitude Operating 10,000 ft (3050 m). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 1500 ft/min (457 m/min). Altitude Non-operating 30,000 ft (9144 m). Maximum allowable altitude change rate is 1500 ft/min (457 m/min). 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

74
Table 9
Hardware Specifications
Item
Components
Thermal solution
Eight 80mm system fans
Table 10
Physical Dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
17.935’’x6.5’’
Dimensions (H x W x D)
(with bezel)
6.96 x 17.64 x 35.32 inch
Server weight (approximate)
Full loading (all memory, hard drives, power supplies, and processors
installed) 68.1kg
Light loading (one piece of memory, one hard drive, and one processor
8 trays installed) 55.2kg
Table 11
Environmental Specifications
Item
Description
Thermal output (maximum operating)
392 W/hr
System inlet temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an altitude derating of
1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct sustained sunlight.
Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or
above 86°F (30°C).
System inlet temperature
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative humidity (non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb
temperature, non-condensing.
Relative humidity (non-condensing)
Non-operating
10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet
bulb temperature, non-condensing.
Altitude
Operating
10,000 ft (3050 m). This value may be limited by the type and number
of options installed. Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Altitude
Non-operating
30,000 ft (9144 m). Maximum allowable altitude change rate is 1500
ft/min (457 m/min).