HP ProLiant SL390s HP ProLiant SL390s G7 1U half width Server Maintenance and - Page 34

Hard Drives, Table 1, Cable, Description, To remove hard drive - g7 1u

Page 34 highlights

Table 1 Cable connection Cable Front SATA cable(Left and right tray) Rear SATA cable(Left and right tray) Rear SATA cable(Left and right tray) From J32 on MB and P1 on personality board J18, J19 on MB and P3, P4 on personality board J9 on MB and P2 on personality board mini SAS to 2x22pin SATA cable(Left and right tray) mini SAS to 4x22pin SATA(Left and right tray) P410 card P410 card Health LED J21 on MB To LFF HDD (configure 2) SFF HDD (configure 1) LFF HDD (configure 2) LFF HDD (configure 3) SFF HDD (configure 4) Hard Drives One SL390s G7 1U server tray can accommodate up to 2 LFF or 4 SFF hard disk drives, one chassis can accommodate 8 1U server trays for up to 16 LFF or 32 SFF hard disk drives. The server supports both SAS and SATA hard disk drives and SSDs. Figure 6 Hard Drive location Item Description 1 SAS/SATA Hard Drive 1 2 SAS/SATA Hard Drive 2 To remove hard drive: Removal and Replacement Procedures 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

Removal and Replacement Procedures 34
Table 1
Cable connection
Cable
From
To
Front SATA cable
Left and right
tray
J32 on MB
and P1 on personality board
LFF HDD
(configure 2)
Rear SATA cable
Left and right
tray
J18, J19 on MB
and P3, P4 on personality board
SFF HDD
(configure 1)
Rear SATA cable
Left and right
tray
J9 on MB
and P2 on personality board
LFF HDD (configure 2)
mini SAS to 2x22pin SATA
cable
Left and right tray
P410 card
LFF HDD (configure 3)
mini SAS to 4x22pin SATA
Left and
right tray
P410 card
SFF HDD (configure 4)
Health LED
J21 on MB
Hard Drives
One SL390s G7 1U server tray can accommodate up to 2 LFF or 4 SFF hard disk drives, one chassis
can accommodate 8 1U server trays for up to 16 LFF or 32 SFF hard disk drives. The server supports
both SAS and SATA hard disk drives and SSDs.
Figure 6
Hard Drive location
Item
Description
1
SAS/SATA Hard Drive 1
2
SAS/SATA Hard Drive 2
To remove hard drive: