MS_System Error Messages The following can be displayed: ■ Explanation: Exchange of Platform Service database between fabrics has failed because activation of MS Platform Services failed on the other switch. Recommended Action: The other switch may not support MS Platform Service. Check capability using the command mscapabilityshow. ■ Explanation: Exchange of Platform Service database between fabrics has failed due to the failure of conditional activation of MS Platform Services on the other switch. Recommended Action: Contact Technical Support. ■ Explanation: Exchange of Platform Service database between fabrics has failed due to conflicting databases between the switches. Recommended Action: Ensure mergeability of connecting fabrics. For example, some DB objects may have conflicting definitions. Issue the command msplatshow to show content of DB and check for conflicts. ■ Explanation: Exchange of Platform Service database between fabrics has failed due to the violation of the size allowance for the MS Platform database. Recommended Action: Ensure that the merged databases will not have a final database size that exceeds the MS Platform database size limitation of 32 kB. ■ Explanation: Exceeded number of tries to merge MS Platform database with another fabric. Errors may be present in the fabric intercommunication. Recommended Action: Check the cable and logical link to ensure healthy cable connections and retry the fabric merge. If the error recurs, contact Technical Support. ■ Explanation: Security is currently enforced and the configuration state of the MS Platform Service between merging fabrics is inconsistent. Diagnostic and System Error Messages Version 3.1.x Reference Guide 67