HP StorageWorks 16-EL diagnostic and system error messages version 3.1.x refer - Page 75
PS_System Error Messages, PS-ASSERT, Message, Explanation, Recommended Action, Severity, PS-MALLOC
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
PS_System Error Messages PS_System Error Messages The Performance Server daemon measures the amount of traffic between end points or it measures traffic with particular frame formats, such as SCSI frames, IP frames, and customer-defined frames. PS-ASSERT Message Error PS-ASSERT, 2, ASSERT PS: Assertion failed : Function: () Explanation The software assertion failed. The is the number of arguments in the assertion, is the expression causing the assertion, is the file name, is the line number, and is the function name. The provide additional information about this assertion. Recommended Action Run the supportshow command, copy the error message output, and send both to Technical Support. Severity Error PS-MALLOC Message Error PS-MALLOC, 2, malloc failed Explanation The switch failed memory allocation. The information provided in describes where in the code the error occurred, for engineering troubleshooting. Diagnostic and System Error Messages Version 3.1.x Reference Guide 75