HP StorageWorks 16-EL diagnostic and system error messages version 3.1.x refer - Page 85
SEC_System Error Messages, SEC-RSENDFAIL, Message, Explanation, Recommended Action, Severity
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
SEC_System Error Messages SEC_System Error Messages This section describes security errors, warnings, and information that occur during secure-related data management or fabric merge in secure mode. Administrators should pay more attention to secure fabric to distinguish between internal switch or fabric operation error or external attack. In case of external attack, the administrator should react properly to stop the attack and protect the fabric. SEC-RSENDFAIL Message Error SEC-RSENDFAIL, 2, RCS process fails: %s Explanation The Reliable Commit Service (RCS) process failed to complete. RCS is a reliable mechanism to transfer data from one switch to the other switches within the fabric. This mechanism guarantees that either all switches update to the new database or none of them update to the new database. This process can fail if one switch in the fabric is either busy or in an error state that cannot accept the database. Recommended Action RCS is used when the security database is changed by a command issued by security (for example, secpolicysave, secpolicyactivate, secversionreset, and the like). If the switch is busy, the command may fail the first time only. Retry after first fail. If the command fails consistently, contact Technical Support. Severity Error Diagnostic and System Error Messages Version 3.1.x Reference Guide 85