HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 21
Documentation Updates, StorageWorks Diagnostics and System Error Messages Reference Guide
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Documentation Updates Documentation Updates Table 4 lists error messages that were not available during the release of the HP StorageWorks Diagnostics and System Error Messages Reference Guide. Table 4: Version 3.1.2 Error Messages Not Previously Available Severity & Message Critical DIAG-BADINT, 1 Critical DIAG-BUS_TIMEOUT, 1 Critical DIAG-CAMFLTR, 1 Probable Cause Port received an unexpected interrupt. This usually indicates an ASIC failure. This message is generated by the centralmemorytest or the cmitest command, if problems are found. ASIC register or ASIC SRAM did not respond to an ASIC data access. This usually indicates an ASIC failure. This message is generated by the portregtest or the sramretentiontest command, if problems are found. ASIC internal logic failed. This usually indicates an ASIC failure. This message is generated by the filtertest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. SAN Switch 2/16 Fabric OS 3.1.2 Release Notes 21