HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 23

For the SAN Switch 2/16SAN, The ASIC Central Memory SRAMs

Page 23 highlights

Documentation Updates Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued) Severity & Message Critical DIAG-CMBISRTO, 1 Critical DIAG-CMERRPTN, 1 Critical DIAG-CMERRTYPE, 1 Critical DIAG-CMICKSUM, 1 Critical DIAG-CMIDATA, 1 Critical DIAG-CMIINVCAP, 1 Critical DIAG-CMINOCAP, 1 Probable Cause The ASIC Central Memory SRAMs did not complete the BISR within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Error detected at the wrong port. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Port got the wrong CMEM error type. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. CMI message received failed. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. CMI data received did not match data transmitted. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Unintended ASIC erroneously got CMI capture flag. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. CMI intended receiver ASIC failed to get CMI capture flag. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. SAN Switch 2/16 Fabric OS 3.1.2 Release Notes 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Documentation Updates
23
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Critical
DIAG-CMBISRTO, 1
The ASIC Central Memory SRAMs
did not complete the BISR within the
timeout period. This usually
indicates an ASIC failure. This
message is generated by the
centralmemorytest
command,
if problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMERRPTN, 1
Error detected at the wrong port.
This usually indicates an ASIC
failure. This message is generated
by the
centralmemorytest
command, if problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMERRTYPE, 1
Port got the wrong CMEM error
type. This usually indicates an ASIC
failure. This message is generated
by the
centralmemorytest
command, if problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMICKSUM, 1
CMI message received failed. This
usually indicates an ASIC or
motherboard failure. This message
is generated by the
cmitest
command, if problems are found.
For the SAN Switch 2/16SAN
Switch 2/16, replace the
motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMIDATA, 1
CMI data received did not match
data transmitted. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the
cmitest
command, if
problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMIINVCAP, 1
Unintended ASIC erroneously got
CMI capture flag. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the
cmitest
command, if
problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-CMINOCAP, 1
CMI intended receiver ASIC failed
to get CMI capture flag. This usually
indicates an ASIC or motherboard
failure. This message is generated
by the
cmitest
command, if
problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Table 4:
Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Probable Cause
Recommended Action