HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 30
spinsilk, portloopbacktest, portregtest, sramretentiontest, Documentation Updates
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Documentation Updates Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued) Severity & Message Critical DIAG-PORTM2M, 1 Critical DIAG-PORTSTOPPED, 1 Critical DIAG-PORTWRONG, 1 Warning DIAG-POST_SKIPPED, 4 Critical DIAG-REGERR, 1 Critical DIAG-REGERR_UNRST, 1 Probable Cause Port is connected to itself (self-loopback). This port M to M port connection is not allowed by the test. This message usually indicates improper cable connections. This message is generated by the spinsilk command, if problems are found. Port is no longer transmitting, as indicated by the Number Of Frames Transmitted counter being stuck at N frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the spinsilk command, if problems are found. Frame erroneously received by port M instead of the intended port N. This usually indicates an ASIC failure. This message is generated by the portloopbacktest command, if problems are found. POST was not executed on the last boot up. Data read from ASIC register or ASIC SRAM did not match data previously written into the same location. This usually indicates an ASIC failure. This message is generated by the portregtest or the sramretentiontest commands, if problems are found. Port failed to unreset. This usually indicates an ASIC failure. This message is generated by the portregtest or the sramretentiontest commands, if problems are found. Recommended Action Reconnect port (M) to a different port (N) and re-execute the test. Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. This message is for information purposes only; no action is required. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. 30 SAN Switch 2/16 Fabric OS 3.1.2 Release Notes