HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 32
replace the motherboard FRU., must replace the entire switch.
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Documentation Updates Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued) Severity & Message Critical DIAG-TIMEOUT, 1 Critical DIAG-XMIT, 1 Probable Cause For portloopbacktest and crossporttest: Port failed to receive frame within timeout period. For centralmemorytest: Port failed to detect an interrupt within the timeout period. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. Port failed to transmit frame. This usually indicates an ASIC failure. This message is generated by the camtest, portloopbacktest, and spinsilk commands, if problems are found. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. 32 SAN Switch 2/16 Fabric OS 3.1.2 Release Notes