HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 32

replace the motherboard FRU., must replace the entire switch.

Page 32 highlights

Documentation Updates Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued) Severity & Message Critical DIAG-TIMEOUT, 1 Critical DIAG-XMIT, 1 Probable Cause For portloopbacktest and crossporttest: Port failed to receive frame within timeout period. For centralmemorytest: Port failed to detect an interrupt within the timeout period. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. Port failed to transmit frame. This usually indicates an ASIC failure. This message is generated by the camtest, portloopbacktest, and spinsilk commands, if problems are found. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. 32 SAN Switch 2/16 Fabric OS 3.1.2 Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Documentation Updates
32
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Critical
DIAG-TIMEOUT, 1
For
portloopbacktest
and
crossporttest
:
Port failed to receive frame within
timeout period.
For
centralmemorytest
:
Port failed to detect an interrupt
within the timeout period.
This can be caused by a faulty cable
or deteriorated SFP. It can also
indicate deeper problems in the
motherboard or ASIC.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Critical
DIAG-XMIT, 1
Port failed to transmit frame. This
usually indicates an ASIC failure.
This message is generated by the
camtest
,
portloopbacktest
,
and
spinsilk
commands, if
problems are found.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Table 4:
Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Probable Cause
Recommended Action