HP StorageWorks 16-EL HP StorageWorks SAN Switch 2/16 Fabric OS V3.1.2 Release - Page 28
Central memory read short: M bytes, requested but not received.
View all HP StorageWorks 16-EL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Documentation Updates Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued) Severity & Message Critical DIAG-INTNOTCLR, 1 Critical DIAG-LCMEM, 1 Critical DIAG-LCMEMTX, 1 Critical DIAG-LCMRS, 1 Critical DIAG-LCMTO, 1 Critical DIAG-MEMNULL, 1 Probable Cause The interrupt bit could not be cleared. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Data read from the memory location did not match data previously written into the same location. This usually indicates an ASIC failure. This message is generated by the centralmemorytest and cmemretentiontest commands, if problems are found. Central memory transmit path failure: ASIC 1 failed to read ASIC 2 using the transmit path. This usually indicates a motherboard failure. This message is generated by the centralmemorytest command, if problems are found. Central memory read short: M bytes requested but not received. This usually indicates an ASIC failure. This message is generated by the centralmemorytest and the cmemretentiontest commands, if problems are found. Central memory timeout: Data transfer initiated did not complete within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest and the cmemretentiontest commands, if problems are found. The ASIC failed to malloc. This usually indicates a a motherboard failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, you must replace the entire switch. 28 SAN Switch 2/16 Fabric OS 3.1.2 Release Notes