rp5400 Series of Servers Carrier Grade Systems Specifications, Table 1-2, Electrical Specifications

Page 32 highlights

Installation Connecting the Server to DC Power Source rp5400 Series of Servers Carrier Grade Systems Specifications The following table lists the power and environmental specifications for the rp5400 Series of Servers Carrier Grade System. For other specifications, refer to the rp5400 Series of Servers documentation. Table 1-2 Electrical Specifications Specification Data Input per Power Supply -48V, 24.5 A -60V, 16 A Maximum System Input Current 38 A Shutdown Thresholds -72V (input over-voltage) -40V (input under-voltage) Maximum Output Power per DC Supply 735 W Power Temperature Ranges: Operating: Non-operating: 5° to 35° C (41° to 95° F) -40° to 65°C (-40° to 149°F) Remote (switched ground) RESET signal: -48V, 50mA (minimum) 500mA (maximum) Alarm signals: Dry relay contact closure for all alarms 20 Chapter 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Chapter 1
Installation
Connecting the Server to DC Power Source
20
rp5400 Series of Servers Carrier Grade Systems Specifications
The following table lists the power and environmental specifications for the rp5400 Series of Servers
Carrier Grade System. For other specifications, refer to the rp5400 Series of Servers documentation.
Table 1-2
Electrical Specifications
Specification
Data
Input per Power Supply
-48V, 24.5 A
-60V, 16 A
Maximum System Input Current
38 A
Shutdown Thresholds
-72V (input over-voltage)
-40V (input under-voltage)
Maximum Output Power per DC Supply
Power
735 W
Temperature Ranges:
Operating:
Non-operating:
5° to 35° C (41° to 95° F)
-40° to 65°C (-40° to
149°F)
Remote (switched ground) RESET signal:
-48V, 50mA (minimum)
500mA (maximum)
Alarm signals:
Dry relay contact closure
for all alarms