HP rp7440 Installation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 - Page 15

Server Front View Without Bezel

Page 15 highlights

Figure 1-3 Server (Front View Without Bezel) The server has the following dimensions: • Depth: Defined by cable management constraints to fit into standard 36-inch deep rack: 25.5 inches from front rack column to PCI connector surface 26.7 inches from front rack column to MP Core I/O connector surface 30 inches overall package dimension, including 2.7 inches protruding in front of the front rack columns. • Width: 44.45 cm (17.5 inches), constrained by EIA standard 19 inch racks. • Height: 10U - 0.54 cm = 43.91 cm (17.287 inches). This is the appropriate height for a product that consumes 10U of rack height while allowing adequate clearance between products directly above and below this product. Fitting four server units per 2 m rack and upgrade of current 10U height products in the future are the main height constraints. The mass storage section located in the front enables access to the 3.5-inch hard drives without removal of the bezel. This is especially helpful when the system is mounted in the lowest position in a rack. The mass storage bay also accommodates one 5.25-inch removable media device. The front panel display board, containing LEDs and the system power switch, is located directly above the 5.25-inch removable media bay. Below the mass storage section and behind the removable front bezel are two, N+1 PCI-X power supplies. The bulk power supply section is partitioned by a sealed metallic enclosure located in the bottom of the package. This enclosure houses the N+1 fully redundant BPSs. Install these power supplies from the front of the server after removing the front bezel. Detailed Server Description 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

Figure 1-3 Server (Front View Without Bezel)
The server has the following dimensions:
Depth: Defined by cable management constraints to fit into standard 36-inch deep rack:
25.5 inches from front rack column to PCI connector surface
26.7 inches from front rack column to MP Core I/O connector surface
30 inches overall package dimension, including 2.7 inches protruding in front of the front
rack columns.
Width: 44.45 cm (17.5 inches), constrained by EIA standard 19 inch racks.
Height: 10U – 0.54 cm = 43.91 cm (17.287 inches). This is the appropriate height for a product
that consumes 10U of rack height while allowing adequate clearance between products
directly above and below this product. Fitting four server units per 2 m rack and upgrade
of current 10U height products in the future are the main height constraints.
The mass storage section located in the front enables access to the 3.5-inch hard drives without
removal of the bezel. This is especially helpful when the system is mounted in the lowest position
in a rack. The mass storage bay also accommodates one 5.25-inch removable media device. The
front panel display board, containing LEDs and the system power switch, is located directly
above the 5.25-inch removable media bay.
Below the mass storage section and behind the removable front bezel are two, N+1 PCI-X power
supplies.
The bulk power supply section is partitioned by a sealed metallic enclosure located in the bottom
of the package. This enclosure houses the N+1 fully redundant BPSs. Install these power supplies
from the front of the server after removing the front bezel.
Detailed Server Description