Icom IC-V80 Instruction Manual - Page 51

Initial Set mode items

Page 51 highlights

SET MODES 10 ■ Initial Set mode items D Key-touch beep Turns the key-touch beep ON (the beep level 1 to 3) or OFF. • When changing the beep level, beeps sound at the level. (default: bEP. 2) D Time-out timer To prevent accidental prolonged transmission, the trans- ceiver has a time-out timer. This function cuts transmission OFF after 1-30 min. of continuous transmission. To turn the function OFF, select "tot.OF." (default: tot. 5) • tot.OF : Turns the function OFF. • tot. 1-30 : If continuous transmission exceeds the selected period, the transmission will be cut off. Approx. 10 sec. before the time-out timer is activated, the transceiver emits a beep tone as a warning. Be careful! When using the BP-263 battery case, the batteries will become hot if this time-out timer function is turned OFF or set to a long time period, and transmission is made for long periods. 1 D Auto repeater U.S.A. version only 2 The Auto Repeater function automatically turns ON or OFF 3 the duplex operation and the tone encoder. The offset and 4 the repeater tone are not changed by the function. Reset these settings, if necessary. 5 • RPt.OF : Turns the function OFF. 6 • RPt.R1 : Activates for only duplex. (default) • RPt.R2 : A ctivates for both duplex and tone. 7 8 9 10 D Auto power-OFF 11 The transceiver can be set to beep and automatically turn OFF, when no key operation occurs during a specified period. 12 • POF.OF : Turns the function OFF. (default) 13 • POF.30/1H/2H : The transceiver is automatically turned OFF when no operation occurs during the selected period. 14 15 16 17 NOTE: The setting is maintained even after the trans- ceiver is turned OFF by the auto power-OFF function. To 18 cancel the function, select "POF.OF." 19 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

44
10
10
SET MODES
Initial Set mode items
D
Key-touch beep
Turns the key-touch beep ON (the beep level 1 to 3) or OFF.
• When changing the beep level, beeps sound at the level.
(default: bEP. 2)
D
Time-out timer
To prevent accidental prolonged transmission, the trans-
ceiver has a time-out timer. This function cuts transmission
OFF after 1–30 min. of continuous transmission.
To turn the function OFF, select “tot.OF.”
(default: tot. 5)
• tot.OF
: Turns the function OFF.
• tot. 1–30 :
If continuous transmission exceeds the selected period,
the transmission will be cut off.
Approx. 10 sec. before the time-out timer is activated, the
transceiver emits a beep tone as a warning.
Be careful!
When using the BP-263 battery case,
the
batteries will become hot if this time-out timer function is
turned OFF or set to a long time period, and transmission
is made for long periods.
D
Auto repeater
The Auto Repeater function automatically turns ON or OFF
the duplex operation and the tone encoder. The offset and
the repeater tone are not changed by the function. Reset
these settings, if necessary.
• RPt.OF
: Turns the function OFF.
• RPt.R1
: Activates for only duplex. (default)
• RPt.R2
:
Activates for both duplex and tone.
D
Auto power-OFF
The transceiver can be set to beep and automatically turn
OFF,
when no key operation occurs during a specified period.
• POF.OF
: Turns the function OFF. (default)
• POF.30/1H/2H :
The transceiver is automatically turned OFF when
no operation occurs during the selected period.
NOTE:
The setting is maintained even after the trans-
ceiver is turned OFF by the auto power-OFF function. To
cancel the function, select “POF.OF.”
U.S.A. version only
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
19