Boxed Processor Contents, 1U Passive/3U+ Active Combination Heat Sink Solution 1U Rack
UPC - 735858191418
View all Intel E5345 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Boxed Processor Specifications 8.3.2.1 8.3.2.2 8.3.2.3 8.4 1U Passive/3U+ Active Combination Heat Sink Solution (1U Rack Passive) In the 1U configuration it is assumed that a chassis duct will be implemented to provide a minimum airflow of 15 cfm at 0.38 in. H2O (25.5 m3/hr at 94.6 Pa) of flow impedance. The duct should be carefully designed to minimize the airflow bypass around the heatsink. It is assumed that a 40°C TLA is met. This requires a superior ochf a3s5s°isC.dFeosilglonwtionglimthietsteheguTiRdIeSlEinaetsowr ibllealollwow5°thCewditehsiagnneerxttoermnaeleatmQbuiaedn-tCtoermepIenrtaetl®ure Xeon® Processor X5300 Series Thermal Profile and conform to the thermal requirements of the processor. 1U Passive/3U+ Active Combination Heat Sink Solution (Pedestal Active) The active configuration of the combination solution is designed to help pedestal chassis users to meet the thermal processor requirements without the use of chassis ducting. It may be still be necessary to implement some form of chassis air guide or air duct to meet the TLA temperature of 40°C depending on the pedestal chassis layout. Also, while the active thermal solution design will mechanically fit into a 2U volumetric, it may not provide adequate airflow. This is due to the requirement of additional space at the top of the thermal solution to allow sufficient airflow into the heat sink fan. Use of the active configuration in a 2U rackmount chassis is not recommended. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. The air passing directly over the processor thermal solution should not be preheated by other system components. Meeting the processor's temperature specification is the responsibility of the system integrator. 2U Passive Heat Sink Solution (2U+ Rack or Pedestal) In the 2U+ passive configuration it is assumed that a chassis duct will be implemented to provide a minimum airflow of 27 cfm at 0.182 in. H2O (45.9 m3/hr at 45.3 Pa) of flow impedance. The duct should be carefully designed to minimize the airflow bypass around the heatsink. The TLA temperature of 40°C should be met. This may require the use of superior design techniques to keep TRISE at or below 5°C based on an ambient external temperature of 35°C. Boxed Processor Contents A direct chassis attach method must be used to avoid problems related to shock and vibration, due to the weight of the thermal solution required to cool the processor. The board must not bend beyond specification in order to avoid damage. The boxed processor contains the components necessary to solve both issues. The boxed processor will include the following items: • Quad-Core Intel® Xeon® Processor 5300 Series • Unattached heat sink solution • Four screws, four springs, and four heat sink standoffs (all captive to the heat sink) • Foam air bypass pad and skirt (included with 1U passive/3U+ active solution) • Thermal interface material (pre-applied on heat sink) • Installation and warranty manual • Intel Inside Logo Quad-Core Intel® Xeon® Processor 5300 Series Datasheet 109