Konica Minolta bizhub PRESS 1250 Watkiss PowerSquare Sheet Feeder User Manual - Page 83
OMR Calibration Procedure, with the OMR Mark FACE DOWN.
View all Konica Minolta bizhub PRESS 1250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
9.4.2 OMR Calibration Procedure The OMR sensors are factory set for a black mark on a white background sheet. However, if the contrast is different (for example, a black mark on a grey background), the operator can calibrate the OMR sensors. - Put "OMR calibration sheet" in the High Pile and the Drawer station (with the OMR Mark FACE DOWN). - Validate the paper size setup in the PSF menu. - Press on the "OMR Calibration" button and validate your choice by pressing OK. OMR Calibration - Select the sensor to calibrate (Drawer or High Pile) and validate your choice by pressing . Operator Manual Initial issue: 05/11 Page 9 - 83 Latest revision: 03/13
Operator Manual
Page 9 - 83
Initial issue: 05/11
Latest revision: 03/13
9.4.2 OMR Calibration Procedure
The OMR sensors are factory set for a black mark on a white background sheet.
However, if the contrast is different (for example, a black mark on a grey background),
the operator can calibrate the OMR sensors.
- Put OMR calibration sheet in the High Pile and the Drawer station
(with the OMR Mark FACE DOWN).
- Validate the paper size setup in the PSF menu.
- Press on the OMR Calibration button and validate your choice by pressing OK.
- Select the sensor to calibrate (Drawer or High Pile) and validate your choice by pressing
.
OMR
Calibration