Konica Minolta magicolor 1600W Service Manual - Page 109
When there is no media, the actuator drops into the slit in the media lift plate, thus block
View all Konica Minolta magicolor 1600W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Lower Feeder Unit 4. Operation Theory of Operation Ver. 1.0 Nov. 2008 4.2 Media Empty Detection • The media empty sensor (PS10) of the PC control board (PCCB) detects a media empty condition in the lower feeder unit. • When there is media loaded in the lower feeder unit, the actuator is raised, which unblocks the sensor. • When there is no media, the actuator drops into the slit in the media lift plate, thus blocking the sensor. Media empty sensor (PS10) At paper empty condition Under normal condition A0VPT2C506AA COMPOSITION/ OPERATION 6
4. Operation
Theory of Operation
V
er. 1.0
N
ov. 200
8
6
Lower Feeder Unit
COMPOSITION/
OPERATION
4.2
Media Empty Detection
•
The media empty sensor (PS10) of the PC control board (PCCB) detects a media empty
condition in the lower feeder unit.
•
When there is media loaded in the lower feeder unit, the actuator is raised, which
unblocks the sensor.
•
When there is no media, the actuator drops into the slit in the media lift plate, thus block-
ing the sensor.
A0VPT2C506AA
Media empty sensor (PS10)
At paper empty condition
Under normal condition