LG HMC030KD1 Service Manual - Page 27
plate.Engage
View all LG HMC030KD1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
5. Indoor unit installation • Hook the indoor unit onto the upper portion of the installation plate.(Engage the three hooks of the rear top and rear lower of the indoor unit with the upper edge and lower edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right. Installation plate Setting line • When extending the drain hose at the indoor unit, install the drain pipe. Drain hose 0 Indoor unit drain hose Adhesive Vinyl tape (narrow) Indoor unit _....„--Three upper (,LI', hooks Installation -- plate Three lower hooks 7. Wrap the insulation material around the connecting portion. ■ Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap. Plastic bands Insulation material 6. Connecting the pipings to the indoor unit and the drain hose to drain pipe. ■ Align the center of the pipings and sufficiently tighten the flare nut by hand. 311Pir. Indoor unit tubing Flare nut Pipings • Tighten the flare nut with a wrench. • Wrap the area which accommodates the rear piping housing section with vinyl tape. Connection pipe (Vwinidyel )tape Indoor unit piping Wrap with vinyl tape Torque wrench Indoor unit tubing Spanner (fixed) Flare nut Connection pipe Capacity (Btu/h) 30K Pipe Size[Torque] Suction Evaporator 5/8"[6.6kg.rn] 3/8"[4.2kg.rn] Connecting cable Pipe Vinyl tape(narrow) - 27 -