LG HMC036KDT1 Service Manual - Page 20
Functions
View all LG HMC036KDT1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Functions Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature • Room temperature sensor. (THERMISTOR) Room temperature control • Maintains the room temperature in accordance with the Setting Temp. Starting Current Control • Indoor fan is delayed for 5 seconds at the starling. Time Delay Safety Control • Restarting is inhibited for approx. 3 minutes. Indoor Fan Speed Control • High, Med, Low, Chaos Operation indication Lamps (LED) 0 (9 OUT DOOR --- Lights up in operation --- Lights up in Sleep Mode --- Lights up in Timer Mode --- Lights up in Deice Mode(for Heat pump model) --- Lights up in Compressor operation(for Cooling model) Health Dehumidification Operation • Intermittent operation of fan at low speed. Sleep Mode Auto Control • The fan is switched to low(Cooling), med(Heating) speed. • The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours. Natural Air Control by CHAOS Logic • The fan is switched to intermittent or irregular operation • The fan speed is automatically switched from high to low speed. Airflow Direction Control • The louver can be set at the desired position or swing up and down automatically. Deice (defrost) control (Heating) • Both the indoor and outdoor fan stops during deicing. • Hot start after deice ends. Hot-start Control (Heating) • The indoor fan stops until the evaporator piping temperature will be reached at 28°C. 20 MPS Multi Air Conditioner