Connection, Pipings, piping
View all LG HMC036KDT1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
2) Connection of Pipings 1. Remove the installation plate • Pull the two 'A' marked portion of bottom of the chassis and pull the installation plate out of chassis. 2. Route the drain hose and the indoor tubing. Installation plate Installation Pull Pull For left rear piping 3. Route the tubing and the drain hose straight backwards(see figure). 4. Insert the connecting cable into the indoor unit through the piping hole. • Do not connect the cable to the indoor unit. • Make a small loop with the cable for easy connection later. 5. Tape the tubing, drain hose and the connecting cable. Be sure that drain hose locates at the lowest side of the bundle. Locating at the upper side can be a reason that drain water overflows drain pan inside the unit. Tubing holder • To remove the holder, press the bottom of the chassis near the holder upwards and the tab is clear of its hole. • Turn it clockwise approx. 90 °and remove it. (2) Pull (:) Press I Connecting cable Gas side piping Liquid side piping ❑rain hose Service Manual 45