LG HMC036KDT1 Service Manual - Page 36
product, operate, remote, contro
View all LG HMC036KDT1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Electronic Parts Troubleshooting Guide 2. The product is not operate with the remote contro Turn on Main Power While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped. When the compressor stopped Indoor Fan is driven by a low speed. At this point the wind speed is not controlled by the remote controller. (When operated in the Sleeping Mode, the wind speed is set to the low speed by force.) Cause by the remote control Caused by other parts except the remote control When the mark( ) is displayed in LCD screen, replace battery. Check the contact of CN-DISPI connector. When the detect switch(double key) inside the remote controller door is fault, it is impossible to operate temperature regulating( rim) and wind speed selecting. Check DISP PWB Ass'y - Voltage between CN DISP1 - ® : DC -F5V Check the connecting circuit between the remote controller MICOM (No. (t) - R17(2Q) - IR LED - O1 R16(2.2Kr2). Check point • Check the connecting circuit between PIN (DR01L(1K) - C0IL(680PF) - MICOM PIN • Check Receiver Ass'y 36 MPS Multi Air Conditioner