LG LMCN185HV Installation Instructions - Page 26
Cealing Cassette Type]
View all LG LMCN185HV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Installation [Cealing Cassette Type] Ceiling dimension and hanging bolt location • The dimensions of the paper model for installation are the same as those of the ceiling opening dimensions. Ceiling Level gauge Ceiling board 523(20 19/32) 319(12 9/16) 570(22 15/32) Unit Size 517(20 3/8) 585~660(23 1/16~26) (Ceiling Opening) 585~660(23 1/16~26) (Ceiling Opening) 517(20 3/8) 570(22 15/32) Unit Size • Select and mark the position for fixing bolts and piping hole. • Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. • Drill the hole for anchor bolt on the wall. 461(18 5/32) Unit: mm(inch) CAUTION : • This air-conditioner uses a drain pump. • Install the unit horizontally using a level gauge. • During the installation, care should be taken not to damage electric wires. NOTICE • Avoid the following installation location. 1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions; • Make sure that ventilation fan is enough to cover all noxious gases from this place. • Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam. 2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. Air conditioner 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5. Avoid places near high frequency generators. Take enough distance Cooking table Use the ventilation fan for smoke-collecting hood with sufficient capacity. 26 Multi Air Conditioner