LG LMCN185HV Installation Instructions - Page 32

Drain Piping

Page 32 highlights

Installation CAUTION: Install certainly the decorative panel. Cool air leakage causes sweating. Water drops fall. Good example Air conditioner unit Bad example Air conditioner unit Air Cool air leakage (no good) Ceiling board Decorative panel Fit the insulator (this part) and be careful for cool air leakage HEAT INSULATION Ceiling board Decorative panel 1. Use the heat insulation material for the refrigerant piping which has an excellent heat- resistance [over 120°C(248°F)]. 2. Precautions in high humidity Fastening band (accessory) circumstance: This air conditioner has been tested according to the "KS Standard Conditions with Mist" and confirmed that there is not any default. However, if Refrigerant piping it is operated for a long time in high Indoor unit humid atmosphere [dew point temperature: more than 23°C(73.4°F)], Thermal insulator (accessory) water drops are liable to fall. In this case, add heat insulation material according to the following procedure: • Heat insulation material to be prepared... Adiabatic glass wool with thickness 10 to 20mm. • Stick glass wool on all air conditioners that are located in ceiling atmosphere. Drain Piping [Standard /Artcool Mirror Type] 1. The drain hose should point downward for optimum drainage. Downward slope 2. Incorrect Installation Examples: Do not raise Accumulated drain water Air Water leakage Water leakage Kinking 32 Multi Air Conditioner Tip of drain hose dipped in water Water leakage Ditch Flexible drain hose Less than 50mm (1 31/32 inch) gap

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

32
Multi Air Conditioner
Installation
CAUTION:
Install certainly the decorative panel.
Cool air leakage causes sweating.
Water drops fall.
Air conditioner
unit
Ceiling
board
Decorative panel
Decorative
panel
Fit the insulator (this part) and
be careful for cool air leakage
Good example
Air
Cool air leakage
(no good)
Bad example
Ceiling
board
Air conditioner unit
HEAT INSULATION
1. Use the heat insulation material for the refrigerant piping which has an excellent heat-
resistance [over 120
°
C(248
°
F)].
2. Precautions in high humidity
circumstance:
This air conditioner has been tested
according to the "KS Standard
Conditions with Mist" and confirmed
that there is not any default. However, if
it is operated for a long time in high
humid atmosphere [dew point
temperature: more than 23
°
C(73.4
°
F)],
water drops are liable to fall. In this
case, add heat insulation material
according to the following procedure:
Heat insulation material to be prepared... Adiabatic glass wool with thickness 10 to 20mm.
Stick glass wool on all air conditioners that are located in ceiling atmosphere.
Indoor unit
Thermal insulator
(accessory)
Fastening band
(accessory)
Refrigerant piping
Drain Piping
1. The drain hose should point downward for
optimum drainage.
2. Incorrect Installation Examples:
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Kinking
Water
leakage
Water
leakage
Ditch
Less than 50mm
(1 31/32 inch) gap
Water
leakage
[Standard /Artcool Mirror Type]