Lenovo ThinkServer RD340 (English) User Guide - Page 81

Running a consistency check, Installing and using the MegaRAID Storage Manager program

Page 81 highlights

To configure the rebuild rate using the LSI Software RAID Configuration Utility program, do the following: Note: Using a rebuild rate of 0 or 100 percent is not recommended. The default value is 30 percent. 1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID Configuration Utility program" on page 65. 2. On the main interface of the program, select Objects ➙ Adapter ➙ Rebuild Rate. 3. Set the rebuild rate by typing a desired value from the keyboard directly. Running a consistency check This topic provides instructions on how to run a consistency check for virtual drives using the LSI Software RAID Configuration Utility program. The consistency check operation verifies that all stripes on a virtual drive with a redundant RAID level (RAID 1, RAID 5, and RAID 10) are consistent and the date on the virtual drive is correct. For example, in a system with parity, checking consistency means computing the data on one drive and comparing the results to the contents of the parity drive. You should run a consistency check on fault-tolerant virtual drives periodically. It is recommended that you run a consistency check at least once a month. You must run a consistency check if you suspect that the virtual drive data might be corrupted. Ensure that you back up the data before running a consistency check if you suspect that the data might be corrupted. To run a consistency check using the LSI Software RAID Configuration Utility program, do the following: 1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID Configuration Utility program" on page 65. 2. On the main interface of the program, select Check Consistency and follow the instructions on the screen. The consistency check rate is the rate at which consistency check operations are run on a system. The consistency check rate can be configured between 0 percent and 100 percent. At 0 percent, the consistency check is done only if the system is not doing anything else. At 100 percent, the consistency check has a higher priority than any other system activity. To configure the consistency check rate using the LSI Software RAID Configuration Utility program, do the following: Note: Using a consistency check rate of 0 or 100 percent is not recommended. The default value is 30 percent. 1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID Configuration Utility program" on page 65. 2. On the main interface of the program, select Objects ➙ Adapter ➙ Chk Const Rate. 3. Set the consistency check rate by typing a desired value from the keyboard directly. Installing and using the MegaRAID Storage Manager program You can install and use the MegaRAID Storage Manager program to manage the RAID array and RAID controller in an operating system environment after configuring RAID. The installation package for the MegaRAID Storage Manager program is on the ThinkServer EasyStartup DVD. After you enter the operating system, insert the ThinkServer EasyStartup DVD into the optical drive. The installation package for the MegaRAID Storage Manager program is located in the Utilities and Others folder in the root directory of the DVD. Chapter 5. Configuring the server 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

ToconfiguretherebuildrateusingtheLSISoftwareRAIDConfigurationUtilityprogram,dothefollowing:
Note:
Usingarebuildrateof0or100percentisnotrecommended.Thedefaultvalueis30percent.
1. Start the LSI Software RAID Configuration Utility program. See “Starting the LSI Software RAID
Configuration Utility program” on page 65.
2. On the main interface of the program, select
Objects
Adapter
Rebuild Rate
.
3. Set the rebuild rate by typing a desired value from the keyboard directly.
Running a consistency check
ThistopicprovidesinstructionsonhowtorunaconsistencycheckforvirtualdrivesusingtheLSISoftware
RAID Configuration Utility program.
TheconsistencycheckoperationverifiesthatallstripesonavirtualdrivewitharedundantRAIDlevel(RAID
1,RAID5,andRAID10)areconsistentandthedateonthevirtualdriveiscorrect.Forexample,inasystem
with parity, checking consistency means computing the data on one drive and comparing the results to
the contents of the parity drive.
Youshouldrunaconsistencycheckonfault-tolerantvirtualdrivesperiodically.Itisrecommendedthatyou
runaconsistencycheckatleastonceamonth.Youmustrunaconsistencycheckifyoususpectthatthe
virtualdrivedatamightbecorrupted.Ensurethatyoubackupthedatabeforerunningaconsistencycheck
if you suspect that the data might be corrupted.
TorunaconsistencycheckusingtheLSISoftwareRAIDConfigurationUtilityprogram,dothefollowing:
1. Start the LSI Software RAID Configuration Utility program. See “Starting the LSI Software RAID
Configuration Utility program” on page 65.
2. On the main interface of the program, select
Check Consistency
and follow the instructions on the
screen.
The consistency check rate is the rate at which consistency check operations are run on a system. The
consistencycheckratecanbeconfiguredbetween0percentand100percent.At0percent,theconsistency
check is done only if the system is not doing anything else. At 100 percent, the consistency check has a
higher priority than any other system activity.
To configure the consistency check rate using the LSI Software RAID Configuration Utility program, do
the following:
Note:
Using a consistency check rate of 0 or 100 percent is not recommended. The default value is 30
percent.
1. Start the LSI Software RAID Configuration Utility program. See “Starting the LSI Software RAID
Configuration Utility program” on page 65.
2. On the main interface of the program, select
Objects
Adapter
Chk Const Rate
.
3. Set the consistency check rate by typing a desired value from the keyboard directly.
Installing and using the MegaRAID Storage Manager program
You can install and use the MegaRAID Storage Manager program to manage the RAID array and RAID
controller in an operating system environment after configuring RAID.
TheinstallationpackagefortheMegaRAIDStorageManagerprogramisonthe
ThinkServerEasyStartup
DVD.Afteryouentertheoperatingsystem,insertthe
ThinkServerEasyStartup
DVDintotheopticaldrive.
TheinstallationpackagefortheMegaRAIDStorageManagerprogramislocatedintheUtilitiesandOthers
folder in the root directory of the DVD.
Chapter 5
.
Configuring the server
69