4500 Operator panel button service check FRU Operator panel Operator panel cable Action Open controller card cage and locate the connection for the operator panel (J2 for E320/E322 or J18 for E220/E321/E323). Check for continuity between pins 1 and 2 as you press the button (or Continue button E220/E321/E323). Similarly, check the continuity between pins 1 and 6 while pressing Cancel (E220/E321/E323). • If continuity is not present, replace the operator panel. Note: Check margin alignments after replacing the operator panel assembly. See "Printhead assembly " on page 4-2 (steps 1through 11) for more information. If margin errors are unacceptable, corrections can only be made through software. Contact the next level of support or Lexmark at 1-800-539-6275. 2-78 Service Manual