4500-E220/E321/E323 Invalid code secondary light patterns Ready/Data Toner Low Load/Remove Paper Paper Jam Error Press Continue Status ● ❍● ❍● ❍ Invalid engine code ● ❍✳ ❍● ❍ Invalid network code Paper Jam secondary light patterns Ready/Data Toner Low Load/Remove Paper Paper Jam Error Press Continue Attendance Condition ● ❍ ❍● ❍ ● Paper jam-input sensor ❍● ❍● ❍ ● Paper jam-exit sensor ❍✳ ❍● ❍ ● Paper jam-duplex sensor ❍ ❍ ● ● ❍ ● Paper jam-fuser exit sensor ✳ ❍ ❍● ❍ ● Paper jam-multipurpose feeder sensor 2-40 Service Manual
2-40
Service Manual
4500–E220/E321/E323
Invalid code secondary light patterns
Paper Jam secondary light patterns
Ready/Data
Toner Low
Load/Remove Paper
Paper Jam
Error
Press Continue
Status
●
❍
●
❍
●
❍
Invalid engine code
●
❍
✳
❍
●
❍
Invalid network code
Ready/Data
Toner Low
Load/Remove Paper
Paper Jam
Error
Press Continue
Attendance Condition
●
❍
❍
●
❍
●
Paper jam–input sensor
❍
●
❍
●
❍
●
Paper jam–exit sensor
❍
✳
❍
●
❍
●
Paper jam–duplex sensor
❍
❍
●
●
❍
●
Paper jam–fuser exit sensor
✳
❍
❍
●
❍
●
Paper jam–multipurpose
feeder sensor