Maytag MER5775RAB Installation Manual - Page 2

Installation, Drawings - range

Page 2 highlights

INSTALLATION DRAWINGS I PLEASE KEIEMPPOFORRTATHNET USE OF THE LOCAL ELECTRICAL INSPECTOR. FIGURE 1 NOTE: Figure may not be representative of actual unit. "A" = 30 inches (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet, or "A" = 24 inches (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4-inch (6.4 mm) thick flame-retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015-inch (0.381 mm) thick stainless steel, 0.024-inch (0.610 mm) thick aluminum, or 0.020-inch (0.508 mm) thick copper. To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches (13 cm) beyond the bottom of the cabinets. FIGURE 1 1, 2, 3 - COMBUSTIBLE BUILDING WALLS. 4 - COMBUSTIBLE WALL CABINET. A free-standing range may be installed adjacent to (0" from) combustible walls 1, 2 & 3. NOTE: FOR INSTALLATION IN CANADA, A FREE-STANDING RANGE IS NOT TO BE INSTALLED CLOSER THAN 12MM FROM ANY ADJACENT SURFACE. "A" : 30" (76,2 CM) - 3E" (78.7 CM) FOR CANADA "B" : 3 J14" (8.3 CM} - 3 3/4" (9.5 CM) FOR CANADA 3G" 191,5 CM COUNTERTOP HEIGHT "A" CABINET 0_[ UPPER & LOWER FIGURE 2 PROVIDE FOR 12012DB VOLT, 1201240 VOLT OUTLET BOX PER APPLICABLE CORD IN THIS AREA -2-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

INSTALLATION
DRAWINGS
I
IMPORTANT
PLEASE
KEEP
FOR THE
USE OF THE
LOCAL
ELECTRICAL
INSPECTOR.
FIGURE
1
NOTE:
Figure may not be representative
of actual unit.
"A" = 30 inches (76.2 cm) minimum
clearance
between
the
top of the cooking surface and the bottom of an unprotected
wood or metal cabinet, or "A" = 24 inches (61 cm) minimum
when
bottom of wood or metal cabinet is protected
by not
less than 1/4-inch (6.4 mm) thick flame-retardant
millboard
covered with not less than No. 28 MSG sheet steel,
0.015-inch
(0.381 mm) thick stainless steel, 0.024-inch
(0.610 mm) thick aluminum,
or 0.020-inch
(0.508 mm) thick
copper.
To eliminate
the risk of burns or fire by reaching over
heated surface units, cabinet storage
space located above
the surface units should be avoided.
If cabinet storage
is to
be provided,
the risk can be reduced by installing a range
hood that projects horizontally
a minimum
of 5 inches (13
cm) beyond the bottom of the cabinets.
FIGURE
1
1, 2, 3
-
COMBUSTIBLE
BUILDING
WALLS.
4
-
COMBUSTIBLE
WALL
CABINET.
A free-standing
range
may be installed
adjacent
to (0"
from)
combustible
walls
1, 2 & 3.
NOTE:
FOR
INSTALLATION
IN
CANADA,
A
FREE-STANDING
RANGE
IS
NOT
TO
BE INSTALLED
CLOSER
THAN
12MM
FROM
ANY
ADJACENT
SURFACE.
3G"
191,5
CM
COUNTERTOP
HEIGHT
"A"
CABINET 0_[
UPPER & LOWER
"A" : 30" (76,2 CM) - 3E" (78.7 CM) FOR CANADA
"B" : 3 J14" (8.3 CM} - 3 3/4" (9.5 CM) FOR CANADA
PROVIDE FOR
12012DB VOLT,
1201240
VOLT
OUTLET BOX
PER APPLICABLE CORD
IN
THIS
AREA
FIGURE
2
-2-