Maytag MER5775RAB Installation Manual - Page 6
Service, or Conduit, Installation, ACCEPTABLE, INSTALLATION
View all Maytag MER5775RAB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
CONNECTING THE RANGE FIGURE 6 3-Wire Service Cord or Conduit Installation 1. Insure that the copper ground strap IS CONNECTED between the middle post of the main terminal connection block and the range chassis. 2. If bare copper or aluminum wiring is used, attach adapter lugs as shown in figure 6. (See Bare Wire Connection). Torque specifications are shown below. 3. The middle wire of the service cord or ground lead of 3-wire conduit MUST connect to the neutral (middle) post of the main terminal block. The other two wires of the service cord or conduit connect to the outside posts of the main terminal connection block. Polarity is unimportant. If using bare wire, attach wire to appropriate lug as shown. Torque specifications are shown below. 4. An appropriate strain relief for service cord or conduit MUST be attached to the conduit plate. ACCEPTABLE - 3 WIRE PLUG INSTALLATION CONDUIT PLATE MAIN TERMINAL CONNECTIONBLOCK MIDDLEWIRE OF SERVICECORD OR CONDUIT STRAIN RELIEF RED ADAPTER LUGS LOCAIED IN LITERATUREKIT WHITE 8LACK RARF WIRF TOROUF SPECIFICAIION_ LUG ATTACH[O 10 TERMINAL BLOCK - 2g IN-LB 10-14 8 4-6 20 tg-LU 25 IN-LB 35 Ig-LB FORUSE WITH CONDUIT. REMOVE BRACKET. FLIP RE-ATTACHWITH SMALL ALTERNATIVF INSTALLATION _ ///'-.,I_ ///A\\ \/ /A MOUNTEDFLUSH TO WALL OUTLETRECEPTACLETO BE -_ ROTATEDAS SHOWNIF NOT _ FLUSH TO WALL % Z_/ -,.v FIGURE 6 -6-