Panasonic BT-LH1850 Operating Instruction - Page 26

continued, Sub menu, Settings, Description, ANAMO, SD ASPECT, IP mode

Page 26 highlights

Main menu (continued) Sub menu Settings Description MONO *2 OFF ON Switches between color and monochrome (MONO). Color Monochrome • When ON, the CHROMA setting of the picture adjusting knob is fixed at 0. ANAMO *7 OFF ON With an Anamo lens and HD-SDI input, the picture is resized to Anamo magnification (the vertically enlarged signal can be vertically compressed and corrected for display). SD ASPECT *2 4:3 16:9 Sets the aspect ratio for SD signal input. 4:3 display 16:9 display SCAN *2*7 NORMAL UNDER Sets under-scan and normal display. Normal display Under-scan *2 This menu is grayed out when the same item is assigned to the GPI input terminal pin and GPI CONTROL is set to ENABLE. *7 "SCAN" changes are not reflected in Anamo size display. IP mode "MODE1" performs IP conversion using intra-frame interpolation. This monitor suppresses the delay to within 1 field. The factory default is "MODE1". "MODE2" performs IP conversion using intra-field interpolation. Since interpolation is performed only inside a field, this mode is suitable for checking interlace status. „„WB (WHITE BALANCE) adjustment mode Select "VAR1" to "VAR3" for "COLOR TEMP." in the "VIDEO CONFIG" menu to make "WHITE BALANCE VAR1" to "WHITE BALANCE VAR3" (WB) adjustments. The underlined values are factory preset setting values. Sub menu COLOR TEMP.*8 Settings USER 0 - 63 D93 D65 D56 Description Selects the color temperature that will become the basis for adjustment. Adjustable settings 0 - 63 (equivalent to a color temperature range of 3,000 K - 9,300 K) Equivalent to a color temperature of 9,300 K Equivalent to a color temperature of 6,500 K Equivalent to a color temperature of 5,600 K GAIN ▼ Adjusts the GAIN elements Press the rotary knob to switch to RGB direct adjustment mode. (This allows you to begin adjusting GAIN first.) RED GREEN BLUE 0 - 1023 (Factory defaults are color temperature values.) • These are the adjustments made before shipment from the factory. Displays the GAIN elements for RED. (For numerical value confirmation) Displays the GAIN elements for GREEN. (For numerical value confirmation) Displays the GAIN elements for BLUE. (For numerical value confirmation) BIAS ▼ Adjusts the BIAS elements Press the rotary knob to switch to RGB direct adjustment mode. (This allows you to begin adjusting BIAS first.) RED GREEN - 512 - 511 (Factory default: 0) Adjusts the BIAS elements for RED. (For numerical value confirmation) Adjusts the BIAS elements for GREEN. (For numerical value confirmation) BLUE Adjusts the BIAS elements for BLUE. (For numerical value confirmation) RESET ▼ Resets "GAIN RED" - "BIAS BLUE" to color temperature values selected under "COLOR TEMP." *8 Selecting "COLOR TEMP." and pressing the rotary knob after making a change, opens a confirmation screen. Selecting "YES" and pressing the rotary knob in this screen resets selected GAIN and BIAS values to the selected color temperature values. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

26
Main menu
(continued)
Sub menu
Settings
Description
MONO
*
2
OFF
ON
Switches between color and monochrome (MONO).
<OFF>
Color
<ON>
Monochrome
• When ON, the CHROMA setting of the picture adjusting knob is fixed at 0.
ANAMO
*
7
OFF
ON
With an Anamo lens and HD-SDI input, the picture is resized to Anamo
magnification (the vertically enlarged signal can be vertically compressed and
corrected for display).
SD ASPECT
*
2
4:3
16:9
Sets the aspect ratio for SD signal input.
<4:3>
4:3 display
<16:9> 16:9 display
SCAN
*
2
*
7
NORMAL
UNDER
Sets under-scan and normal display.
<NORMAL> Normal display
<UNDER>
Under-scan
*
2
This menu is grayed out when the same item is assigned to the GPI input terminal pin and GPI CONTROL is set to ENABLE.
*
7
“SCAN” changes are not reflected in Anamo size display.
IP mode
“MODE1” performs IP conversion using intra-frame interpolation.
This monitor suppresses the delay to within 1 field.
The factory default is “MODE1”.
“MODE2” performs IP conversion using intra-field interpolation.
Since interpolation is performed only inside a field, this mode is suitable for checking interlace status.
±
WB (WHITE BALANCE) adjustment mode
Select “VAR1” to “VAR3” for “COLOR TEMP.” in the “VIDEO CONFIG” menu to make “WHITE BALANCE VAR1” to “WHITE BAL-
ANCE VAR3” (WB) adjustments.
The underlined values are factory preset setting values.
Sub menu
Settings
Description
COLOR TEMP.
*
8
USER 0 - 63
D93
D65
D56
Selects the color temperature that will become the basis for adjustment.
<USER 0 - 63>
Adjustable settings 0 - 63 (equivalent to a color temperature
range of 3,000 K - 9,300 K)
<D93>
Equivalent to a color temperature of 9,300 K
<D65>
Equivalent to a color temperature of 6,500 K
<D56>
Equivalent to a color temperature of 5,600 K
GAIN
Adjusts the GAIN elements
Press the rotary knob to switch to RGB direct adjustment mode.
(This allows you to begin adjusting GAIN first.)
RED
0 - 1023
(Factory defaults are
color temperature
<D65> values.)
• These are the
adjustments made
before shipment from
the factory.
Displays the GAIN elements for RED. (For numerical value confirmation)
GREEN
Displays the GAIN elements for GREEN. (For numerical value confirmation)
BLUE
Displays the GAIN elements for BLUE. (For numerical value confirmation)
BIAS
Adjusts the BIAS elements
Press the rotary knob to switch to RGB direct adjustment mode.
(This allows you to begin adjusting BIAS first.)
RED
- 512 - 511
(Factory default: 0)
Adjusts the BIAS elements for RED. (For numerical value confirmation)
GREEN
Adjusts the BIAS elements for GREEN. (For numerical value confirmation)
BLUE
Adjusts the BIAS elements for BLUE. (For numerical value confirmation)
RESET
Resets “GAIN RED” - “BIAS BLUE” to color temperature values selected under
“COLOR TEMP.”
*
8
Selecting “COLOR TEMP.” and pressing the rotary knob after making a change, opens a confirmation screen. Selecting “YES” and
pressing the rotary knob in this screen resets selected GAIN and BIAS values to the selected color temperature values.