Panasonic BT-LH1850 Operating Instruction - Page 30

RESET operation, FUNCTION, press the rotary knob.

Page 30 highlights

Main menu (continued) RESET operation 1. Turn the rotary knob in the "SYSTEM CONFIG" menu to select the "CALIBRATION" submenu and press the rotary knob. 2. Turn the rotary knob to select the "RESET" submenu and press the rotary knob. [RESET] YES NO MENU EXIT SEL. ENTER RETURN RETURN 3. Select "YES" and press the rotary knob. This starts calibration. [RESET] xxxxxxxxx MENU EXIT SEL. ENTER RETURN RETURN xxxxxxxxx indicates that the following message with the meaning listed below appears. COMPLETE: Operation completed 4. Turn the power off and then on after performing reset op- eration. FUNCTION The underlined values are factory preset setting values. Sub menu Settings Description FUNCTION 1 FUNCTION 5 HV DELAY BLUE ONLY GAMMA SELECT SD ASPECT SCAN SUB WINDOW WFM/VECTOR MARKER WHITE BALANCE PIXEL TO PIXEL PIXEL POSITION FOCUS-IN-RED LEVEL METER CROSS HATCH MONO BLACK MODE TIME CODE CLOSED CAPTION AUDIO MUTE UNDEF (Factory defaults FUNCTION1: MARKER FUNCTION2: WFM/ VECTOR FUNCTION3: PIXEL TO PIXEL FUNCTION4: TIME CODE FUNCTION5: LEVEL METER) Selects functions to be assigned to [FUNCTION1] - [FUNCTION5] (front panel buttons) or the FUNCTION menu. *1 Displays the image blanking period. The display changes in the following order. DELAY OFF → H DELAY → V DELAY → HV DELAY → DELAY OFF *1 Cuts the red and green signals. Use this function to check phase and chroma. This button toggles between ON and OFF. *2*3 Selects the gamma curve. The display changes in the following order. GAMMA STANDARD → GAMMA FILM → GAMMA STDIO/PST → GAMMA STANDARD *2*3 Switches between "16:9" and "4:3." *2*3 Switches between "UNDER SCAN" and "NORMAL SCAN". *1 Sets the split-screen function. The display changes in the following order. SINGLE → FULL/PART → STILL → SINGLE *2 Displays waveform or vector display. For details on the available operation items, refer to page 33. *2*3*4 Turns the marker on and off. For details on the available operation items, refer to page 33. WHITE BALANCE GAIN/BIAS RGB direct adjustment can only be accessed when VAR1 to VAR3 are selected in COLOR TEMP. Turns the PIXEL TO PIXEL function On and Off. Positions the display of signals in PIXEL TO PIXEL mode. *1 The settings are cancelled when the power is turned OFF. *2 If these settings are changed, the menu settings will also change. *3 The control settings do not operate during GPI operation. *4 Not displayed when "16:9", "4:3" and "CENTER" are all "OFF" in the MARKER menu settings. 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

30
Main menu
(continued)
*
1
The settings are cancelled when the power is turned OFF.
*
2
If these settings are changed, the menu settings will also change.
*
3
The control settings do not operate during GPI operation.
*
4
Not displayed when “16:9”, “4:3” and “CENTER” are all “OFF” in the MARKER menu settings.
RESET operation
1.
Turn the rotary knob in the “SYSTEM CONFIG” menu to
select the “CALIBRATION” submenu and press the rotary
knob.
2.
Turn the rotary knob to select the “RESET” submenu and
press the rotary knob.
MENU EXIT
RETURN
RETURN
SEL.
ENTER
[RESET]
YES
NO
3.
Select “YES” and press the rotary knob.
This starts calibration.
MENU EXIT
RETURN
RETURN
SEL.
ENTER
[RESET]
xxxxxxxxx
xxxxxxxxx indicates that the following message with the mean-
ing listed below appears.
COMPLETE: Operation completed
4.
Turn the power off and then on after performing reset op-
eration.
FUNCTION
The underlined values are factory preset setting values.
Sub menu
Settings
Description
FUNCTION 1 -
FUNCTION 5
HV DELAY
BLUE ONLY
GAMMA SELECT
SD ASPECT
SCAN
SUB WINDOW
WFM/VECTOR
MARKER
WHITE BALANCE
PIXEL TO PIXEL
PIXEL POSITION
FOCUS-IN-RED
LEVEL METER
CROSS HATCH
MONO
BLACK MODE
TIME CODE
CLOSED CAPTION
AUDIO MUTE
UNDEF
(Factory defaults
FUNCTION1:
MARKER
FUNCTION2: WFM/
VECTOR
FUNCTION3: PIXEL
TO PIXEL
FUNCTION4: TIME
CODE
FUNCTION5: LEVEL
METER)
Selects functions to be assigned to [FUNCTION1] - [FUNCTION5] (front panel
buttons) or the FUNCTION menu.
<HV DELAY>
*
1
Displays the image blanking period.
The display changes in the following order.
DELAY OFF → H DELAY → V DELAY → HV DELAY → DELAY OFF
<BLUE ONLY>
*
1
Cuts the red and green signals. Use this function to check phase and chroma. This
button toggles between ON and OFF.
<GAMMA SELECT>
*
2
*
3
Selects the gamma curve.
The display changes in the following order.
GAMMA STANDARD → GAMMA FILM → GAMMA STDIO/PST →
GAMMA STANDARD
<SD ASPECT>
*
2
*
3
Switches between “16:9” and “4:3.”
<SCAN>
*
2
*
3
Switches between “UNDER SCAN” and “NORMAL SCAN”.
<SUB WINDOW>
*
1
Sets the split-screen function.
The display changes in the following order.
SINGLE → FULL/PART → STILL → SINGLE
<WFM/VECTOR>
*
2
Displays waveform or vector display.
For details on the available operation items, refer to page 33.
<MARKER>
*
2
*
3
*
4
Turns the marker on and off.
For details on the available operation items, refer to page 33.
<WHITE BALANCE>
WHITE BALANCE GAIN/BIAS RGB direct adjustment can only be accessed when
VAR1 to VAR3 are selected in COLOR TEMP.
<PIXEL TO PIXEL>
Turns the PIXEL TO PIXEL function On and Off.
<PIXEL POSITION>
Positions the display of signals in PIXEL TO PIXEL mode.