Panasonic BT-LH1850 Operating Instruction - Page 41

Control, Hours Meter, Rs-485 Stx&etx

Page 41 highlights

Main menu (continued) Sub menu Settings Description IN MONITOR DISPLAY OFF ON Enables IMD display. POSITION TOP BOTTOM Selects the position for the IMD display. Top Bottom CHAR. COLOR CMD WHITE BLUE GREEN YELLOW CYAN RED GRAY MAGENTA Selects IMD font color. Color specified by command*3 White Blue Green Yellow Cyan Red Gray Magenta *3 When colors selected by commands are set to "OFF," the IMD character string is not displayed. CONTROL The underlined values are factory preset setting values. Sub menu CONTROL Settings LOCAL REMOTE Description Selects operation. (with control lock) Front panel operation is enabled (including controls that use the GPI function) Remote operation enabled (controls using RS-232C or RS-485). (Front panel operation is locked) • Power On/Off, VOLUME operations, GPI control and menu display are available when the lock is engaged. • Only "CONTROL/LOCAL ENABLE" menu items are available when the lock is engaged. • The rotary knob is disabled and set values cannot be changed when the lock is engaged. • The "LOCAL ENABLE" setting determines operations in lock mode. • The key icon appears in the operation status display, menu display (main menu, FUNCTION menu, INPUT SELECT menu), picture adjustment menu display, and function display screens when the lock is engaged. LOCAL ENABLE *1 DISABLE INPUT FUNCTION INPUT+FUNC. PROTOCOL VER. *2 RS-485 ID SETUP RS-485 STX&ETX V3.1 V4.0 0-126 OFF ON [MARKER] MARKER OFF Key icon 16:9 4:3 4:3 OFF Selects whether toBCeAEnCNaKTbElRe or disable INNPORUMOTAFLFSELECT and FUNCTION button operations when "RCREOMSOS TE" is selected unOdFeFr "CONTROL." G CPOIDLisOMaRAbRlKeEsRI1NPUT95S%E(LW1EH6I:CT9TE)and FUNCTION button operations. G PIEnMaAbRleKsERIN2PUT95S%E(L1E6C:9T)button operations. M ENUEEnXIaTbles SFELU. NCETNTIEOR NREbTURuN tRtEoTUnRN operations. Enables INPUT SELECT and FUNCTION button operations. Selects version of the TSL protocol. Sets the unit ID number to use in RS-485 communication. Select RS-485 interface command format (→page 46). STX and ETX need not be placed. STX and ETX must be placed. *1 Only available when "REMOTE" is selected under "CONTROL." *2 The monitor supports version 3.1 and 4.0 of the TSL UMD PROTOCOL provided by Television System LTD. HOURS METER Sub menu Settings Description OPERATION XXXXXXh *1 Displays the number of hours it has been on. LCD XXXXXXh *1 Displays the number of hours that the backlight has been on. *1 "XXXXXX" indicates up to 262800 hours (approx. 30 years). "OVER" is indicated when the number of hours is 262800 or higher. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

41
Main menu
(continued)
Sub menu
Settings
Description
IN MONITOR DISPLAY
OFF
ON
Enables IMD display.
POSITION
TOP
BOTTOM
Selects the position for the IMD display.
<TOP>
Top
<BOTTOM> Bottom
CHAR. COLOR
CMD
WHITE
BLUE
GREEN
YELLOW
CYAN
RED
GRAY
MAGENTA
Selects IMD font color.
<CMD>
Color specified by command
*
3
<WHITE>
White
<BLUE>
Blue
<GREEN>
Green
<YELLOW>
Yellow
<CYAN>
Cyan
<RED>
Red
<GRAY>
Gray
<MAGENTA> Magenta
*
3
When colors selected by commands are set to “OFF,” the IMD character string is not displayed.
CONTROL
The underlined values are factory preset setting values.
Sub menu
Settings
Description
CONTROL
LOCAL
REMOTE
Selects operation. (with control lock)
<LOCAL>
Front panel operation is enabled (including controls that use the GPI
function)
<REMOTE>
Remote operation enabled (controls using RS-232C or RS-485). (Front
panel operation is locked)
• Power On/Off, VOLUME operations, GPI control and menu display are
available when the lock is engaged.
• Only “CONTROL/LOCAL ENABLE” menu items are available when the
lock is engaged.
• The rotary knob is disabled and set values cannot be changed when the
lock is engaged.
• The “LOCAL ENABLE” setting determines operations in lock mode.
• The key icon appears in the operation status display, menu display (main
menu, FUNCTION menu, INPUT SELECT menu), picture adjustment
menu display, and function display screens when the lock is engaged.
[MARKER]
MARKER
16:9
4:3
OFF
4:3
OFF
Key icon
LOCAL ENABLE
*
1
DISABLE
INPUT
FUNCTION
INPUT+FUNC.
Selects whether to enable or disable INPUT SELECT and FUNCTION button
operations when “REMOTE” is selected under “CONTROL.”
<DISABLE>
Disables INPUT SELECT and FUNCTION button operations.
<INPUT>
Enables INPUT SELECT button operations.
<FUNCTION>
Enables FUNCTION button operations.
<INPUT+FUNC.>
Enables INPUT SELECT and FUNCTION button operations.
PROTOCOL VER.
*
2
V3.1
V4.0
Selects version of the TSL protocol.
RS-485 ID SETUP
0-126
Sets the unit ID number to use in RS-485 communication.
RS-485 STX&ETX
OFF
ON
Select RS-485 interface command format (→page 46).
<OFF>
STX and ETX need not be placed.
<ON>
STX and ETX must be placed.
*
1
Only available when “REMOTE” is selected under “CONTROL.”
*
2
The monitor supports version 3.1 and 4.0 of the TSL UMD PROTOCOL provided by Television System LTD.
HOURS METER
Sub menu
Settings
Description
OPERATION
XXXXXXh
*
1
Displays the number of hours it has been on.
LCD
XXXXXXh
*
1
Displays the number of hours that the backlight has been on.
*
1
“XXXXXX” indicates up to 262800 hours (approx. 30 years). “OVER” is indicated when the number of hours is 262800 or higher.