Sharp AL 800 AL-800 AL-840 Operation Manual - Page 27

USER PROGRAMS, power save modes, auto clear time - user manual

Page 27 highlights

TONER SAVE MODE 2 Press and hold down the exposure mode selector key for approximately 5 seconds. The manual ( ) indicator will go out and the photo ( ) indicator will begin to blink. The exposure indicator marked "5" will light up, indicating the standard toner mode is active. 3 To enter the toner save mode, press the light ( ) key. The exposure indicator marked "1" will light up, indicating the toner save mode is selected. 4 Special functions 4 Press the exposure mode selector key twice.The photo ( ) indicator will stop blinking and the AUTO indicator will light up steadily. The toner save mode is now active. To return to the standard mode, repeat the procedure but use the dark ( ) key to select exposure level "5" in step 3. USER PROGRAMS (power save modes, auto clear time) The user programs allow the parameters of certain functions to be set, changed, or canceled as desired. Paper must be present in the paper tray before user programs can be accessed. Setting the power save modes and auto clear time 1 Press and hold down the light ( ) and dark ( ) keys simultaneously for more than 5 seconds until all the alarm indicators ( , , ) blink and "- -" appears in the display. 2 Use the left copy quantity ( ) key to select a user program number (1: auto clear time, 2: preheat mode, 3: auto power shut-off timer, 5: auto power shut-off mode, 9: paper detection mode). The selected number will blink in the left side of the display. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

26
4
Special functions
TONER SAVE MODE
2
Press and hold down the exposure mode selector key for approximately 5 seconds.
The manual (
) indicator will go out and the photo (
) indicator will begin to blink.
The exposure indicator marked “5” will light up, indicating the standard toner mode is
active.
3
To enter the toner save mode, press the light (
) key.
The exposure indicator marked “1” will light up, indicating the toner save mode is
selected.
4
Press the exposure mode selector key twice. The photo (
) indicator will stop blinking
and the AUTO indicator will light up steadily. The toner save mode is now active.
To return to the standard mode, repeat the procedure but use the dark (
)
key to select exposure level “5” in step 3.
USER PROGRAMS
(power save modes, auto clear time)
The user programs allow the parameters of certain functions to be set, changed, or canceled
as desired.
Paper must be present in the paper tray before user programs can be accessed.
Setting the power save modes and auto clear time
1
Press and hold down the light (
) and dark (
) keys simultaneously for more than
5 seconds until all the alarm indicators (
,
,
) blink and “– –” appears in the
display.
2
Use the left copy quantity (
) key to select a user program number (1: auto clear
time, 2: preheat mode, 3: auto power shut-off timer, 5: auto power shut-off mode, 9:
paper detection mode). The selected number will blink in the left side of the display.