Sharp PG-B10S Operation Manual - Page 67

Maintenance Indicators - repair

Page 67 highlights

Maintenance Indicators I The warning lights on the projector indicate problems inside the projector. I If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the projector will enter the standby mode. After the projector has entered the standby mode, follow the procedures given below. Temperature warning indicator Lamp indicator Power indicator About the lamp indicator About the temperature warning indicator If the temperature inside the projector increases, due to blockage of the air vents, or the setting location, " " will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and then the projector will enter the standby mode. After " " appears, be sure to perform the following measures. I The lamp life becomes 0%, when used for approximately 4,000 hours with "Eco Mode" or when used for approximately 2,000 hours with "Standard Mode" (see page 43). I When the remaining lamp life becomes 5% or less, " " (yellow) will be displayed on the screen. When the percentage be- comes 0%, " " will change to " " (red), the lamp will automatically turn off and then the projector will automatically enter the standby mode. At this time, the lamp indicator will illuminate in red. I If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on. Maintenance indicator Normal Abnormal Temperature warning indicator Off Red on/ Standby Condition The internal temperature is abnormally high. Problem Possible Solution • Blocked air intake • Relocate the projector to an area with proper ventilation. • Clean the air filter of the projector. (See page 61.) • Cooling fan break- • Take the projector to your nearest down Sharp Authorized Projector Dealer • Internal circuit failure or Service Center (see page 73) • Clogged air intake for repair. Lamp indicator Green on Green blinks when the lamp is warming up. Red on Red on/ Standby Time to change the lamp. The lamp does not illuminate. • Carefully replace the lamp. (See • Remaining lamp life page 66.) becomes 5% or less. • Take the projector to your nearest Sharp Authorized Projector Dealer or Service Center (see page 73) • Burnt-out lamp for repair. • Lamp circuit failure • Please exercise care when replacing the lamp. Power Green on/ indicator Red on Red blinks The power indicator blinks in red when the projector is on. • The filter cover or lamp unit cover is open. • Securely install the cover. • If the power indicator blinks in red even when the filter cover and lamp unit cover is securely installed, contact your nearest Sharp Authorized Projector Dealer or Service Center for advice. -63 Appendix

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

-63
Appendix
Maintenance Indicators
The warning lights on the projector indicate problems inside the projector.
If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
Temperature warning indicator
Lamp indicator
Power indicator
About the temperature warning indicator
If the temperature inside the
projector increases, due to
blockage of the air vents, or the
setting location,
will
illuminate in the lower left corner of the picture. If
the temperature keeps on rising, the lamp will turn off
and the temperature warning indicator will blink, the
cooling fan will run for a further 90 seconds, and then
the projector will enter the standby mode. After
appears, be sure to perform the following
measures.
About the lamp indicator
The lamp life becomes 0%, when used
for approximately 4,000 hours with
Eco
Mode
or when used for approximately
2,000 hours with
Standard Mode
(see
page
43
).
When the remaining lamp life becomes
5% or less,
(yellow) will be displayed
on the screen. When the percentage be-
comes 0%,
will change to
(red),
the lamp will automatically turn off and
then the projector will automatically en-
ter the standby mode. At this time, the
lamp indicator will illuminate
in red.
If you try to turn on the projector a fourth
time without replacing the lamp, the pro-
jector will not turn on.
Maintenance indicator
Condition
Problem
Possible Solution
Temperature
warning
indicator
Normal
Abnormal
Off
Red on/
Standby
The internal
temperature is
abnormally high.
Abnormal
Blocked air intake
Relocate the projector to an area
with proper ventilation.
Clean the air filter of the projector.
(See page
61
.)
Cooling fan break-
down
Internal circuit failure
Clogged air intake
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page
73
)
for repair.
Lamp
indicator
Red on/
Standby
The lamp does
not illuminate.
Burnt-out lamp
Lamp circuit failure
Carefully replace the lamp. (See
page
66
.)
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page
73
)
for repair.
Please exercise care when
replacing the lamp.
Red on
Time to change
the lamp.
Remaining lamp life
becomes 5% or less.
Power
indicator
The power
indicator blinks
in red when the
projector is on.
The filter cover or
lamp unit cover is
open.
Securely install the cover.
If the power indicator blinks in red
even when the filter cover and
lamp unit cover is securely
installed, contact your nearest
Sharp Authorized Projector Dealer
or Service Center for advice.
Green on/
Red on
Red blinks
Green on
Green blinks
when the
lamp is
warming up.