Page 81 highlights
Code Message 96 SY NV-RAM ERROR 97 SV NV-RAM ERROR 98 NV-RAM ERROR 99 INTERNAL I/F 2 Description Abnormality has been detected in the operation of an NV-RAM (on SY-320 board) for the system control system. Abnormality has been detected in the operation of an NV-RAM (on SV-225 board) for the servo system. Abnormality has been detected in the operation of an NV-RAM (on EQ-101 board) for the RF system or an NV-RAM (on DM-123 board) for the DM system. Abnormality in the interface between SYS CPU (on SY-320 board) and SERVO CPU (on SV-225 board) or MPU (on EQ-101, DM-123, HPR-14, VPR-92, APR-70, and KY-571 board) has been detected. Chapter 10 Maintenance and Inspection 81 Error Messages
81
Error Messages
Chapter 10
Maintenance and Inspection
96
SY NV-RAM ERROR
Abnormality has been detected in the operation of an NV-RAM (on SY-320 board) for the
system control system.
97
SV NV-RAM ERROR
Abnormality has been detected in the operation of an NV-RAM (on SV-225 board) for the
servo system.
98
NV-RAM ERROR
Abnormality has been detected in the operation of an NV-RAM (on EQ-101 board) for the RF
system or an NV-RAM (on DM-123 board) for the DM system.
99
INTERNAL I/F 2
Abnormality in the interface between SYS CPU (on SY-320 board) and SERVO CPU
(on SV-225 board) or MPU (on EQ-101, DM-123, HPR-14, VPR-92, APR-70, and KY-571
board) has been detected.
Code
Message
Description