Toshiba 65HM167 Service Manual - Page 6

To Reduce The Risk Of Electric Shock, Never Remove Tv Covers - replacement lamp

Page 6 highlights

Replacing the Lamp Unit WARNING: RISK OF ELECTRIC SHOCK! TO REDUCE THE RISK OF ELECTRIC SHOCK, NEVER REMOVE TV COVERS, EXCEPT AS SPECIFIED HEREIN. REFER ALL SERVICING NOT SPECIFIED IN THIS MANUAL TO QUALIFIED SERVICE PERSONNEL. Failure to follow this WARNING may result in death or serious injury. The light source for this TV is a mercury lamp with internal atmospheric pressure that increases during use. The lamp has a limited service life that varies depending on product use and user settings. As is generally the case with all projection TVs that use projection lamps as a light source, the brightness of the lamp in this TV may vary somewhat over the expected service life and will generally decrease over time. Because of the many variables that can affect the useful service life of the lamp, your experience may vary from other users. If you use the lamp beyond its service life you may notice a reduction in the colors and/or brightness of the picture. The strength of the quartz glass in the lamp will be reduced and the lamp may rupture (often making a loud noise when this happens). If the lamp ruptures, the TV will not operate until the lamp unit is replaced. CAUTION: Always handle the lamp unit with care. The lamp unit in this TV was designed for safe replacement by consumers; however, if the lamp unit is subjected to intentional abuse (such as excessive mechanical abuse or handling by children or pets), the unit may break, exposing sharp edges or pinch points. WARNING: RISK OF ELECTRIC SHOCK! TO REDUCE THE RISK OF ELECTRIC SHOCK, NEVER REMOVE TV COVERS, EXCEPT AS SPECIFIED HEREIN. REFER ALL SERVICING NOT SPECIFIED IN THIS MANUAL TO QUALIFIED SERVICE PERSONNEL. Failure to follow this WARNING may result in death or serious injury. 1. Turn off the TV and unplug the power cord. WARNING: Eye damage may result from directly viewing the light produced by this lamp. Always turn off the TV and unplug the power cord before opening the lamp unit door. CAUTION! HOT SURFACE! Touching the lamp before it has cooled will result in severe burns. ALLOW THE LAMP TO COOL FOR AT LEAST ONE (1) HOUR BEFORE REPLACING IT. 2. Using a manual, slotted screwdriver, loosen the screw securing the lamp door and remove the door. 3. Using a manual Phillips screwdriver, loosen the two screws on the lamp unit. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Replacing the Lamp Unit
WARNING:
RISK OF ELECTRIC SHOCK!
TO REDUCE THE RISK OF ELECTRIC SHOCK, NEVER REMOVE TV COVERS,
EXCEPT AS SPECIFIED HEREIN.
REFER ALL SERVICING NOT SPECIFIED IN THIS MANUAL TO QUALIFIED SERVICE
PERSONNEL. Failure to follow this WARNING may result in death or serious injury.
The light source for this TV is a mercury lamp with internal atmospheric pressure that increases during use. The lamp has a limited
service life that varies depending on product use and user settings.
As is generally the case with all projection TVs that use projection lamps as a light source, the brightness of the lamp in this TV may
vary somewhat over the expected service life and will generally decrease over time. Because of the many variables that can affect
the useful service life of the lamp, your experience may vary from other users.
If you use the lamp beyond its service life you may notice a reduction in the colors and/or brightness of the picture.
The strength of
the quartz glass in the lamp will be reduced and the lamp may rupture (often making a loud noise when this happens). If the lamp
ruptures, the TV will not operate until the lamp unit is replaced.
CAUTION:
Always handle the lamp unit with care.
The lamp unit in this TV was designed for safe replacement by consumers;
however, if the lamp unit is subjected to intentional abuse (such as excessive mechanical abuse or handling by children or pets), the
unit may break, exposing sharp edges or pinch points.
WARNING:
RISK OF ELECTRIC SHOCK!
TO REDUCE THE RISK OF ELECTRIC SHOCK, NEVER REMOVE TV COVERS,
EXCEPT AS SPECIFIED HEREIN.
REFER ALL SERVICING NOT SPECIFIED IN THIS MANUAL TO QUALIFIED SERVICE
PERSONNEL. Failure to follow this WARNING may result in death or serious injury.
1.
Turn off the TV and unplug the power cord.
WARNING:
Eye damage may result from directly viewing the light produced by this lamp.
Always turn off the TV and unplug
the power cord before opening the lamp unit door.
CAUTION!
HOT SURFACE!
Touching the lamp before it has cooled will result in severe burns. ALLOW THE LAMP TO
COOL FOR AT LEAST ONE (1) HOUR BEFORE REPLACING IT.
2.
Using a manual, slotted screwdriver, loosen the screw securing the lamp door and remove the door.
3.
Using a manual Phillips screwdriver, loosen the two screws on the lamp unit.