ViewSonic PJ1173 PJ1173 User Guide, English - Page 105

Send Data format

Page 105 highlights

Management with Web browser software Command Control via the Network (continued) Command Format Command formats differ among the different communication ports. ● TCP #23 You can use the RS-232C commands without any changes. The reply data format is the same as the RS-232C commands. However, the following reply will be sent back in the event of authentication failure when authentication is enabled. Reply 0x1F Error code 0x04 0x00 ● TCP #9715 Send Data format The following formatting is added to the header (0x02), Data length (0x0D), Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands. Header 0x02 Data length 0x0D RS-232C command 13 bytes Check sum Connection ID 1 byte 1 byte Header → 0x02, Fixed Data length → RS-232C commands byte length (0x0D, Fixed) RS-232C commands → RS-232C commands that start with 0xBE 0xEF (13 bytes) Check Sum → This is the value to make zero on the addition of the lower 8 bits from the header to the checksum. Connection ID → Random value from 0 to 255 (This value is attached to the reply data) ViewSonic 100 PJ1173

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

PJ1173
ViewSonic
±00
Management with Web browser software
Command Control via the Network (continued)
Command Format
Command formats differ among the different communication ports.
● TCP #23
You can use the RS-232C commands without any changes. The reply data
format is the same as the RS-232C commands. However, the following reply
will be sent back in the event of authentication failure when authentication is
enabled.
Header
Data length
RS-232C command
Check sum
Connection
ID
0x0²
0x0D
±3 bytes
± byte
± byte
Reply
Error code
0x±F
0x04
0x00
<Reply in the event of an authentication error>
Header
→ 0x02, Fixed
Data length
→ RS-232C commands byte length (0x0D, Fixed)
RS-232C commands →
RS-232C commands that start with 0xBE 0xEF
(±3 bytes)
Check Sum
This is the value to make zero on the addition of the
lower 8 bits from the header to the checksum.
Connection ID
Random value from 0 to 255 (This value is attached
to the reply data)
● TCP #9715
Send Data format
The following formatting is added to the header (0x0²), Data length (0x0D),
Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands.