SCSI backplane jumper settings and HDD ID assignments
View all Asus AP1710-E1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
SCSI backplane jumper settings and HDD ID assignments The 6-pin jumper J 1 on each of the SCSI backplanes allows you to define your desired SCSI configuration. The picture below shows the location of jumper J1 with pins 1-3 and 2-4 shorted. Refer to the following tables for the jumper settings and the appropriate ID# for each SCSI HDD bay. Setting 1: Using single-channel SCSI/RAID card Cascade configuration First backplane (BP1) J 1 s e t t i n g (1-3 shorted, 2-4 shorted) Device Drive Bay 1 Drive Bay 2 Drive Bay 3 Drive Bay 4 GEM SAF-TE SCSI ID# ID0 ID1 ID2 ID3 ID15 Second backplane (BP2) J 1 s e t t i n g (3-5 shorted, 4-6 shorted) Device Drive Bay 5 Drive Bay 6 Drive Bay 7 Drive Bay 8 GEM SAF-TE SCSI ID# ID4 ID5 ID6 ID8 ID11 2-36 Chapter 2: Hardware setup