Asus TRL-DLS TRL-DLS User Manual - Page 79

NetWare 5.X New Installations, NetWare 4.XX New Installations

Page 79 highlights

5. OS Driver Installation B. NetWare 5.X New Installations 1. Begin the file server installation according to the instructions in the file server installation chapter in the Novell NetWare Installation Manual. 2. When the NetWare installation procedure prompts you a Device type screen, press Modify to add a Storage adapters: (Default only IDEATA available). Press INS for adding a new driver. Please put the Adaptec driver for NetWare diskette into drive A: Then use the INS key to select an unlisted driver. A dialog box appears. If the driver diskette is in the A: drive, press Enter to continue. The ADPT160.HAM drivers appear as a selection. 3. Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press Enter and load an additional driver. Then press the INS key. The system always defaults to the A: path. Highlight the HAM driver and press Enter. Select Yes to save and move the driver into the operating system. Press Enter, the system will copy the files. 4. Load a separate instance of the driver for every Adaptec controller SCSI channel or host adapter present in the system. 5. When prompted for a slot number, accept the slot numbers displayed. Make sure to write these slot numbers down for future reference. 6. When asked to edit the STARTUP.NCF file, make sure that the ADPT160M.HAM is loaded once for each Adaptec SCSI controller channel present in the system. Add the statement SLOT= to each load line in the STARTUP.NCF, by specifying the slot numbers written down in step 5 above, with only one slot number per load instance. The HAM driver(s) are loaded for each Adaptec SCSI controller channel from the first LOAD statement to the last LOAD statement. C. NetWare 4.XX New Installations 1. Begin the file server installation according to the instructions in the file server installation chapter in the Novell NetWare Installation Manual. 2. When the NetWare installation procedure prompts you for a driver disk, insert the Adaptec driver for NetWare diskette into drive A: Then use the INS key to select an unlisted driver. A dialog box appears. If the driver diskette is in the A: drive, press Enter to continue. The ADPT160M.HAM driver appears as a selection. 5. Driver Installation Novell Netware ASUS TRL-DLS User's Manual 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

ASUS TRL-DLS User’s Manual
79
5. OS Driver Installation
5. Driver Installation
Novell Netware
B.
NetWare 5.X New Installations
1.
Begin the file server installation according to the instructions in the file
server installation chapter in the Novell NetWare Installation Manual.
2.
When the NetWare installation procedure prompts you a
Device type
screen,
press
Modify
to add a
Storage adapters
:
(Default only
IDEATA
available).
Press
INS
for adding a new driver. Please put the
Adaptec driver for
NetWare
diskette into drive
A:
Then use the
INS
key to select an unlisted
driver. A dialog box appears. If the driver diskette is in the
A:
drive, press
Enter
to continue. The
ADPT160.HAM
drivers appear as a selection.
3.
Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press
Enter
and load
an additional driver. Then press the
INS
key. The system always defaults to
the
A:
path. Highlight the HAM driver and press
Enter
. Select
Yes
to save
and move the driver into the operating system. Press
Enter,
the system will
copy the files.
4.
Load a separate instance of the driver for every Adaptec controller SCSI
channel or host adapter present in the system.
5.
When prompted for a slot number, accept the slot numbers displayed. Make
sure to write these slot numbers down for future reference.
6.
When asked to edit the STARTUP.NCF file, make sure that the
ADPT160M.HAM is loaded once for each Adaptec SCSI controller channel
present in the system. Add the statement SLOT=<slot number> to each load
line in the STARTUP.NCF, by specifying the slot numbers written down in
step 5 above, with only one slot number per load instance. The HAM
driver(s) are loaded for each Adaptec SCSI controller channel from the first
LOAD statement to the last LOAD statement.
C.
NetWare 4.XX New Installations
1.
Begin the file server installation according to the instructions in the file
server installation chapter in the Novell NetWare Installation Manual.
2.
When the NetWare installation procedure prompts you for a driver disk,
insert the
Adaptec driver for NetWare
diskette into drive
A:
Then use the
INS
key to select an unlisted driver. A dialog box appears. If the driver
diskette is in the
A:
drive, press
Enter
to continue. The
ADPT160M.HAM
driver appears as a selection.