Brother International HL-2400C Users Manual - English - Page 158
Fusing Unit
View all Brother International HL-2400C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 158 highlights
CHAPTER 5 MAINTENANCE Fusing Unit Fusing Unit When the following message appears on the LCD panel, you need to replace the Fusing Unit. REPLACE FUSER Warning The Fusing unit and the parts around it are HOT. Be sure to wait about 30 minutes and check it has cooled down before you start replacing the Fusing unit. If you touch the HOT parts, you might get injured. ! Caution When replacing the fusing unit, wait for approximately 30 minutes before printing after the new unit is installed to allow the fusing oil to circulate in the new fusing unit. Replacing the Fusing Unit 1. Press the Power button and turn the printer off and unplug the printer. Wait for 30 minutes or until the printer has cooled down. 2. Open the Top cover and the Rear Access Cover. 3. Unscrew the screws on both sides inside the Rear Access Cover and release the metal parts. Fig. 5-18 Unscrew and release the Metal Parts 5-17