Compaq ProLiant 1200 ProLiant Server Troubleshooting Guide - Page 117
Table 4-1, Event Messages, 001 of 010, 54 PM, FAN INSERTED, Main System, Location, System Board
View all Compaq ProLiant 1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Diagnostic Tools **001 of 010** ---caution--03/19/2002 12:54 PM FAN INSERTED Main System Location: System Board Fan ID: 03 **END OF EVENT** WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in your server-specific user documentation before removing, replacing, reseating, or modifying system components. Table 4-1: Event Messages Event Message Machine Environment System Fan Failure (Fan X, Location) System Fans Not Redundant System Overheating (Zone X, Location) Main Memory Corrected Memory Error threshold passed (Slot X, Memory Module Y) Corrected Memory Error threshold passed (System Memory) Corrected Memory Error threshold passed (Memory Module unknown) Event Type Fan failure Fans not redundant Overheat condition Correctable error threshold exceeded Action Replace fan. Add new fan or replace defective fan. Check fans. Continue normal operation, and then replace the memory module during the next scheduled maintenance to ensure reliable operation. continued 4-14 HP Servers Troubleshooting Guide