Test Error Codes 6700-6799, SCSI Tape Drive Test Error Codes The 6700 series of diagnostic error codes identifies failures with the tape cartridge, tape drive, media changer, tape drive cabling, SCSI adapter, or system board assembly. Corrective action may require replacement of any of these parts. Table B-14: SCSI Tape Drive Test Error Codes Error Code 6700-XX 6706-XX 6708-XX 6709-XX 6728-XX Description SCSI Tape ID drive types test failed SCSI Disk SA/Media test failed SCSI Controller test failed SCSI Disk Erase tape test failed Media load/unload test failed Recommended Action The following steps apply to error codes 6700-XX through 6728-XX: 1. Run the server setup utility and check drive type. 2. Replace the SCSI Tape drive signal and power cables and retest. 3. Replace the SCSI controller and retest. 4. Replace the SCSI Tape drive and retest. 5. Replace the system board assembly and retest. 8600-8699, Pointing Device Interface Test Error Codes The 8600 series of diagnostic error codes identifies failures with the pointing device (mouse, trackball, and so forth) or the system board assembly. Corrective action may require replacement of the pointing device or the system board assembly. Table B-15: Pointing Device Interface Test Error Codes Error Code 8601-XX Description Pointing Device Interface test failed Recommended Action 1. Replace with working pointing device and retest. 2. Replace the system board and retest. HP Servers Troubleshooting Guide B-15