Compaq ProLiant 1200 ProLiant Server Troubleshooting Guide - Page 230
XC-50, S.M.A.R.T. Hard
View all Compaq ProLiant 1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 230 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1720-S.M.A.R.T. Hard Drive Detects Imminent Failure None This is a prefailure notification of a SCSI hard drive that will fail soon. 1721-Slot X Drive Array - Drive parameter tracking predicts imminent failure. The following devices should be replaced when conditions permit. Do not replace drive unless all other drives in the array are on-line! Back up data before replacing drive(s) if using RAID 0. None Drive parameter tracking predictive-failure condition. Monitor and Performance threshold exceeded. Action • If configured as a non-RAID 0 array, replace the failing/failed drive. Refer to the maintenance and service guide for more information on when and how to replace the drive. • If configured as a RAID 0 array or non-RAID setup, back up the drive or drives, replace, and restore. Drive parameter tracking reports a predictive-failure condition on the indicated drive. It may fail at some time in the future. • If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and restore all data afterward. • If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the array are online. continued C-50 HP Servers Troubleshooting Guide