ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Other controller indicates different cache size The other controller in the redundant controller configuration has a different size array accelerator. Be sure that both controllers are using the same capacity array accelerator. RIS copies between drives do not match The drives on this controller contain copies of the reserve information sector (RIS) that do not match. The hard drives in the array do not have matching configuration information. To remedy this: 1. Resolve all other errors encountered. 2. Obtain the latest version of ADU, and then rerun ADU. 3. If unconfigured drives were added, configure these drives using ACU, which should resolve the error. 4. If drives or arrays were moved, be sure that the movement adheres to the guidelines listed in the documentation for the array controller. 5. If the error persists after completing steps 1 through 4, contact an authorized service provider. SCSI Port X Drive ID Y failed - ADU detected a drive failure. REPLACE (failure message) Correct the condition that caused the error, if possible, or replace the drive. SCSI port X, Drive ID Y firmware needs upgrading Drive firmware may cause problems and should be upgraded. Run Options ROMPaq to upgrade the drive firmware to a later revision. continued D-14 HP Servers Troubleshooting Guide