Compaq ProLiant 1200 ProLiant Server Troubleshooting Guide - Page 258
upload code not, firmware version 2.30 or 2.31.
View all Compaq ProLiant 1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 258 highlights
ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Drive (bay) X is a replacement drive This drive has been replaced. This message is displayed if a drive is replaced in a fault tolerant logical volume. If the replacement was intentional, allow the drive to rebuild. Drive (bay) X is a replacement drive marked OK This drive has been replaced and marked OK by the firmware, which may occur if a drive has an intermittent failure. For example, a drive has previously failed, then starts working again when ADU is run. Replace the drive. Drive (bay) X is failed. The indicated physical drive has failed. Replace this drive. Drive (bay) X is undergoing drive recovery This drive is being rebuilt from the corresponding mirror or parity data. Normal operations should occur. Drive (bay) X needs replacing. The 210-MB hard drive has firmware version 2.30 or 2.31. Replace the drive. Drive (bay) X upload code not readable. An error occurred while ADU was trying to read the upload code information from this drive. If there were multiple errors, this drive may need to be replaced. Drive (bay) X was inadvertently replaced. The physical drive was incorrectly replaced after another drive failed. 1. Replace the drive that was incorrectly replaced. 2. Replace the original drive that failed. Do not run the server setup utility and try to reconfigure; data will be lost. continued D-8 HP Servers Troubleshooting Guide