Compaq ProLiant 1200 ProLiant Server Troubleshooting Guide - Page 183
Table C-2, Non-Numeric Error Messages or Beeps Only, Error Code, Audible, Beeps, Probable Source
View all Compaq ProLiant 1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
POST Error Messages Table C-2: Non-Numeric Error Messages or Beeps Only continued Error Code Audible Beeps Probable Source of Problem Action Beeps only 2 long No valid memory is present in the system. • If no memory modules are present, install at least one memory module to conform to minimum hardware configuration specifications. • Reseat all installed memory modules. • If the system contains more than one memory module, remove one module, and restart the server. Repeat as needed to isolate the bad memory module. Critical Error Occurred Prior to this power-up None A catastrophic system error, which caused the server to crash, has been logged. Run Diagnostics. Replace failed assembly as indicated. Critical Failure Detected - System Shutting Down in None Blower assembly has failed. Replace blower assembly. Critical Fan Failure Detected - System Shutting Down System Halted None A critical fan is not spinning. Check fans. Check fan cable connections. Critical Fan Failure Detected - System Shutting Down in 5 seconds System Halted None A critical fan is not spinning. Check fans. Check fan cable connections. continued HP Servers Troubleshooting Guide C-3