ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action SCSI port X, Drive ID Y has exceeded the following threshold(s) The monitor and performance threshold for this drive has been violated. Check and resolve the threshold that has been violated. SCSI port X, Drive ID Y is not stamped for monitoring The drive has not been stamped with monitor and performance features. To change without destroying the current configuration: 1. Run ACU. 2. Change the array accelerator size and save the configuration. 3. Change the array accelerator back to the original size and save again. This should cause ACU to stamp the drive with monitoring and performance features. SCSI port X, Drive ID Y may have a loose connection SOLUTION: Turn the system off and attempt to reattach any loose connections. If this does not work, replace the cable(s) and connection(s). SMART is unable to communicate with the drive, because the cable is not securely connected, or the drive cage connection has failed. 1. Power down the system. 2. Reconnect the cable securely. 3. Restart the system. 4. If this does not solve the problem, replace the cables and connectors as needed. SCSI port X, Drive ID Y RIS copies within this drive do not match The copies of RIS on the drive Check for other errors. The do not match. drive may need to be replaced. continued HP Servers Troubleshooting Guide D-15