3-26 Compaq ProLiant 8500 Server Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action *1788-Slot X Drive Array Reports Incorrect Drive Replacement. The following SCSI drive(s) should have been replaced: SCSI Port Y: SCSI ID Z The following SCSI drive(s) were incorrectly replaced: SCSI Port Y: SCSI ID Z. None Drives are not installed in their 1. Reinstall the drives original positions, so the drives correctly as indicated. have been disabled. 2. Press F1 to restart the computer with the drive array disabled. -Or- Press F2 to use the drives as configured and lose all the data on them. Select F1 to continue - drive array will remain disabled. Select F2 to reset configuration - all data will be lost. * The 1788 error message can also be displayed inadvertently due to a bad power cable connection to the drive, noise on the data cable, or a defective SCSI cable. If this message was due to a bad power cable connection, but not incorrect drive replacement, repair the connection and press F2. If the message is not eliminated by pressing F2, run Array Diagnostic Utility to resolve. -Or- If this message was not due to a bad power cable connection and no drive replacement took place, this could indicate noise on the data cable. Check cable for proper routing. -Or- If this message is due to a defective SCSI cable, replace the cable. continued