Page 97 highlights
Diagnostic Tools 3-19 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1726-Slot X Drive None Array - Array Accelerator Memory Size Change Detected. - Array Accelerator configuration has been updated automatically. 1727-Slot X Drive None Array - New Logical Drive(s) Attachment Detected. If more than 32 logical drives, this message will be followed by: "Auto-configuration failed: Too many logical drives." 1729-Slot 1 Drive None Array - Disk Consistency Initialization in Progress - RAID 4/5 performance may be lower until Auto Reliability Monitoring has completed Automatic Background Parity Consistency Initialization. 1730-Fixed Disk 0 None does not support DMA Mode. 1731-Fixed Disk 1 None does not support DMA Mode. 1740-Fixed Disk 0 None failed Set Block Mode command 1741-Fixed Disk 1 None failed Set Block Mode command 1750-Fixed Disk 0 None failed Identify command Probable Source of Problem Configuration updated. Additional drives detected. Initial RAID configuration in progress. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Recommended Action This message indicates that the array accelerator configuration has been updated automatically due to replacement of the array accelerator (or controller), with one having different cache memory size. Press F1 key to resume operation. This message indicates that the controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32. Additional logical drives will not be added to the configuration. Press F1 key to resume operation. This message is normal following the initial configuration of RAID 4 or RAID 5 logical drives. Performance of the controller will improve after the parity data has been initialized by ARM (an automatic process that runs in the background on the controller). Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. continued