Compaq ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 97

failed Set Block, Detected. If more

Page 97 highlights

Diagnostic Tools 3-19 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1726-Slot X Drive None Array - Array Accelerator Memory Size Change Detected. - Array Accelerator configuration has been updated automatically. 1727-Slot X Drive None Array - New Logical Drive(s) Attachment Detected. If more than 32 logical drives, this message will be followed by: "Auto-configuration failed: Too many logical drives." 1729-Slot 1 Drive None Array - Disk Consistency Initialization in Progress - RAID 4/5 performance may be lower until Auto Reliability Monitoring has completed Automatic Background Parity Consistency Initialization. 1730-Fixed Disk 0 None does not support DMA Mode. 1731-Fixed Disk 1 None does not support DMA Mode. 1740-Fixed Disk 0 None failed Set Block Mode command 1741-Fixed Disk 1 None failed Set Block Mode command 1750-Fixed Disk 0 None failed Identify command Probable Source of Problem Configuration updated. Additional drives detected. Initial RAID configuration in progress. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Fixed disk drive error detected. Recommended Action This message indicates that the array accelerator configuration has been updated automatically due to replacement of the array accelerator (or controller), with one having different cache memory size. Press F1 key to resume operation. This message indicates that the controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32. Additional logical drives will not be added to the configuration. Press F1 key to resume operation. This message is normal following the initial configuration of RAID 4 or RAID 5 logical drives. Performance of the controller will improve after the parity data has been initialized by ARM (an automatic process that runs in the background on the controller). Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. Run the server setup utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Diagnostic Tools
3-19
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1726-Slot
X
Drive
Array
Array
Accelerator Memory
Size Change
Detected.
Array
Accelerator
configuration has
been updated
automatically.
None
Configuration updated.
This message indicates that the
array accelerator configuration
has been updated automatically
due to replacement of the array
accelerator (or controller), with
one having different cache
memory size. Press
F1
key to
resume operation.
1727-Slot
X
Drive
Array
New Logical
Drive(s) Attachment
Detected. If more
than 32 logical
drives, this message
will be followed by:
Auto-configuration
failed: Too many
logical drives.
None
Additional drives detected.
This message indicates that the
controller has detected an
additional array of drives that
was attached when the power
was off. The logical drive
configuration information has
been updated to add the new
logical drives. The maximum
number of logical drives
supported is 32. Additional
logical drives will not be added
to the configuration. Press
F1
key to resume operation.
1729-Slot 1 Drive
Array
Disk
Consistency
Initialization in
Progress
RAID 4/5
performance may be
lower until Auto
Reliability Monitoring
has completed
Automatic
Background Parity
Consistency
Initialization.
None
Initial RAID configuration in
progress.
This message is normal
following the initial
configuration of RAID 4 or
RAID 5 logical drives.
Performance of the controller
will improve after the parity data
has been initialized by ARM (an
automatic process that runs in
the background on the
controller).
1730-Fixed Disk 0
does not support
DMA Mode.
None
Fixed disk drive error detected.
Run the server setup utility and
correct.
1731-Fixed Disk 1
does not support
DMA Mode.
None
Fixed disk drive error detected.
Run the server setup utility and
correct.
1740-Fixed Disk 0
failed Set Block
Mode command
None
Fixed disk drive error detected.
Run the server setup utility and
correct.
1741-Fixed Disk 1
failed Set Block
Mode command
None
Fixed disk drive error detected.
Run the server setup utility and
correct.
1750-Fixed Disk 0
failed Identify
command
None
Fixed disk drive error detected.
Run the server setup utility and
correct.
continued